By sample application in measured quantities ("injection method") the quality of serum required for the determination of trace elements can be considerably decreased with essentially no loss in sensitivity. The volume of solution, 50 or 100 microliters, required for a single measurement is added to the nebulizer of the AAS apparatus manually with a bulb pipette, or automatically by a suitable sample changing system. A total of 500 microliters serum is sufficient for the determination of traces of Fe, Cu, and Zn. It was shown that under suitable conditions a total volume of 25 microliters serum is sufficient for the determination of Cu and Zn by flame atomic absorption-atomic emission photometry.
Download full-text PDF |
Source |
---|
Scand J Clin Lab Invest
December 2024
Hormone Laboratory, Department of Medical Biochemistry and Biochemical Endocrinology and Metabolism Research Group, Oslo University Hospital, Aker, Oslo, Norway.
Saliva samples offer the possibility to obtain stress-free non-invasive samples, also for home-testing, especially useful when blood collection is either undesirable or difficult. The aim of this work was to develop an LC-MS/MS method to determine clinically relevant steroid hormones cortisol, cortisone, 11-deoxycortisol, 21-deoxycortisol, 17OH-progesterone, aldosterone, corticosterone, deoxycorticosterone, testosterone, androstenedione, DHEAS, DHEA, 17OH-pregnenolone, betamethasone and dexamethasone. A special effort was made to adapt the method to neonatal population with respect to choice of saliva as matrix, low sample volumes, selection of analytes and multiplexing.
View Article and Find Full Text PDFAnal Chem
December 2024
State Key Laboratory of Biogeology and Environmental Geology, School of Earth Sciences, China University of Geosciences, Wuhan 430074, China.
ACS Appl Mater Interfaces
December 2024
Department of Chemistry, University of Puerto Rico at Cayey, 205 Ave. Antonio R Barcelo, Cayey, Puerto Rico 00736, United States.
Liquid marbles (LMs) are microliter-scale droplets coated with hydrophobic solid particles. The particle size and hydrophobicity of the surface coating determine their properties, such as transparency, expandability, and resistance to evaporation and coalescence, one or more of which can be critical to their application as microreactors. This study reports the use of a mixture of two different hydrophobic powders for fabrication of LMs for colorimetric assays: trichloro(1,1,2,2-perfluorooctyl) silane-linked silica gel (modified silica gel (MSG), particle size: 40-75 μm) and hexamethyldisilazane-linked fumed silica (modified fumed silica (MFS), average aggregate length: 200-300 nm).
View Article and Find Full Text PDFAllergy
November 2024
Toulouse Institute for Infectious and Inflammatory Diseases (Infinity), UMR 1291, INSERM, CNRS, University of Toulouse, Toulouse, France.
Background: Diagnosis of allergies is mostly based on the patient's clinical history and allergen provocation tests. Determination of specific IgE (sIgE) profiles can be performed to support allergy diagnosis. This is commonly done in vivo by the skin prick test or in vitro with automated systems.
View Article and Find Full Text PDFAnal Chem
November 2024
Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California San Diego, La Jolla, California 92093, United States.
Diabetes management demands precise monitoring of key biomarkers, particularly insulin (I) and glucose (G). Herein, we present a bioelectronic chip device that enables the simultaneous detection of I and G in biofluids within 2 min. This dual biosensor chip integrates aptamer-based insulin sensing with enzymatic glucose detection on a single platform, employing a four-electrode sensor chip.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!