Download full-text PDF

Source
http://dx.doi.org/10.1016/0047-0740(73)90040-5DOI Listing

Publication Analysis

Top Keywords

digital phantoms
4
phantoms simulation
4
simulation scanning
4
scanning process
4
process evaluate
4
evaluate techniques
4
techniques computer
4
computer focusing
4
focusing area
4
area scans
4

Similar Publications

Irreproducibility in molecular optical sectioning microscopy has hindered the transformation of acquired digital images from qualitative descriptions to quantitative data. Although numerous tools, metrics, and phantoms have been developed, accurate quantitative comparisons of data from different microscopy systems with diverse acquisition conditions remains a challenge. Here, we develop a simple tool based on an absolute measurement of bulk fluorophore solutions with related Poisson photon statistics, to overcome this obstacle.

View Article and Find Full Text PDF

Amyloid PET imaging plays a crucial role in the diagnosis and research of Alzheimer's disease (AD), allowing non-invasive detection of amyloid-β plaques in the brain. However, the low spatial resolution of PET scans limits the accurate quantification of amyloid deposition due to partial volume effects (PVE). In this study, we propose a novel approach to addressing PVE using a latent diffusion model for resolution recovery (LDM-RR) of PET imaging.

View Article and Find Full Text PDF
Article Synopsis
  • Limited-angle dual-energy cone-beam CT (LA-DECBCT) is a promising method for achieving fast, low-dose imaging, but its clinical use is challenged by difficulties in image reconstruction.
  • A new image reconstruction technique using inter-spectral structural similarity was developed to reduce artifacts, improving the quality of DECBCT images without needing extra data for training.
  • This method shows significant potential for practical clinical applications in LA-DECBCT, enabling accurate imaging without relying on X-ray spectra or paired datasets.
View Article and Find Full Text PDF
Article Synopsis
  • Treatment Planning Systems (TPS) are evaluated for their effectiveness in correcting distortions in Magnetic Resonance (MR) images using a virtual phantom and Control Points (CPs).
  • The study involved creating distorted MR images and applying TPS, with findings showing that distortion caused median deviations of 1.8 mm, which were reduced to 0.6 mm after correction.
  • Structural Similarity Metric (SSIM) tests indicated significant improvements in image quality, with the TPS successfully reducing distortions to levels acceptable for radiosurgery.
View Article and Find Full Text PDF
Article Synopsis
  • The study investigated the noise reduction capabilities of a photon-counting detector (PCD) in computed tomography (CT) using a model-based iterative reconstruction algorithm (QIR).
  • Forty repeated scans were conducted on a water phantom and compared with a conventional energy-integrating detector (EID) to assess noise characteristics.
  • Results showed that PCD-CT significantly reduced noise levels and improved image uniformity, demonstrating the effectiveness of QIR in decreasing noise without altering the overall distribution of noise values.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!