Research on retinal circulation during space flight required the development of a simple technique to provide self monitoring of blood vessel changes in the fundus without the use of mydriatics. A Kowa RC-2 fundus camera was modified for self-photography by the use of a bite plate for positioning and cross hairs for focusing the subject's retina relative to the film plane. Dilation of the pupils without the use of mydriatics was accomplished by dark adaption of the subject. Pictures were obtained without pupil constriction by the use of a high speed strobe light. This method also has applications for clinical medicine.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0361-9230(79)90066-2DOI Listing

Publication Analysis

Top Keywords

kowa rc-2
8
rc-2 fundus
8
fundus camera
8
modification kowa
4
camera self-photography
4
self-photography mydriatics
4
mydriatics retinal
4
retinal circulation
4
circulation space
4
space flight
4

Similar Publications

Objective: To describe a means of converting the Kowa RC-2 camera to a digital version.

Procedure: The optic (OP) and the film portions (FP) of the Kowa RC-2 were separated. The lateral rails were unscrewed from the front plate of the FP.

View Article and Find Full Text PDF

To determine if image magnification from ametropia or other factors required correction in the photogrammetric diagnosis of optic nerve hypoplasia, the following variables were studied using two standard 30 degrees field fundus cameras (Zeiss FF-3 and Kowa RC-2): (1) distance between the camera and the subject--variations in this distance do not change the image size; (2) decentration of the camera (i.e., decentration of the optic disc image within the field)--no effect was found using the Kowa camera, but in the Zeiss, a 2% (0.

View Article and Find Full Text PDF

The method for observing the eye-fundus of rhesus monkeys was devised by the use of Kowa RC-2 Hand-held Fundus Camera. 1. For monochrome photography, Fuji Neopan F (ASA 32) and Fuji Neopan SS (ASA 100) films were used.

View Article and Find Full Text PDF

Research on retinal circulation during space flight required the development of a simple technique to provide self monitoring of blood vessel changes in the fundus without the use of mydriatics. A Kowa RC-2 fundus camera was modified for self-photography by the use of a bite plate for positioning and cross hairs for focusing the subject's retina relative to the film plane. Dilation of the pupils without the use of mydriatics was accomplished by dark adaption of the subject.

View Article and Find Full Text PDF