Download full-text PDF

Source
http://dx.doi.org/10.3758/bf03199851DOI Listing

Publication Analysis

Top Keywords

orientation contrast
4
contrast effects
4
effects rod-and-frame
4
rod-and-frame test
4
orientation
1
effects
1
rod-and-frame
1
test
1

Similar Publications

This study investigated silicone composites with distributed boron nitride platelets and carbon microfibers that are oriented electrically. The process involved homogenizing and dispersing nano/microparticles in the liquid polymer, aligning the particles with DC and AC electric fields, and curing the composite with IR radiation to trap particles within chains. This innovative concept utilized two fields to align particles, improving the even distribution of carbon microfibers among BN in the chains.

View Article and Find Full Text PDF

Terrestrial laser scanners (TLS) are portable dimensional measurement instruments used to obtain 3D point clouds of objects in a scene. While TLSs do not require the use of cooperative targets, they are sometimes placed in a scene to fuse or compare data from different instruments or data from the same instrument but from different positions. A contrast target is an example of such a target; it consists of alternating black/white squares that can be printed using a laser printer.

View Article and Find Full Text PDF

Mechanical force-induced interlayer sliding in interfacial ferroelectrics.

Nat Commun

January 2025

Key Laboratory of Polar Materials and Devices (Ministry of Education), Shanghai Center of Brain-Inspired Intelligent Materials and Devices, Department of Electronics, East China Normal University, Shanghai, 200241, China.

Moiré superlattices in two-dimensional stacks have attracted worldwide interest due to their unique electronic properties. A typical example is the moiré ferroelectricity, where adjacent moirés exhibit opposite spontaneous polarization that can be switched through interlayer sliding. However, in contrast to ideal regular ferroelectric moiré domains (equilateral triangles) built in most theoretical models, the unavoidable irregular moiré supercells (non-equilateral triangles) induced by external strain fields during the transfer process have been given less attention.

View Article and Find Full Text PDF

Optimizing TMS dosimetry: evaluating the effective electric field as a novel metric.

Phys Med Biol

January 2025

Department of Information Engineering, Electronics and Telecommunications (DIET) , University of Rome La Sapienza, Via Eudossiana 18, Rome, 00184, ITALY.

Objective: This study introduces the effective electric field (Eeff) as a novel observable for transcranial magnetic stimulation (TMS) numerical dosimetry. Eeff represents the electric field component aligned with the local orientation of cortical and white matter neuronal elements. To assess the utility of Eeff as a predictive measure for TMS outcomes, we evaluated its correlation with TMS induced muscle responses and compared it against conventional observables, including the electric (E-)field magnitude, and its components normal and tangential to the cortical surface.

View Article and Find Full Text PDF

Artificial microstructures, especially metamaterials, have garnered increasing attention in numerous applications due to their rich and distinctive properties. Starting from the principle of multi-beam interference, we have theoretically devised a beam configuration consisting of six symmetrically distributed coherent beams to generate two-dimensional microstructures with diverse shapes of unitcells under different polarization combinations. In particular, a split-ring metamaterial template is achieved with two adjacent circularly and four linearly polarized beams with such single-step holographic interferometry.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!