A multidiscipline group was established at The Pennsylvania State University to design and evaluate mechanical circulatory assist devices and the artificial heart. The group has designed a left ventricular to aortic assist system which consists of a sac-type pump, a synchronization unit, a pneumatic power unit, and appropriate monitoring apparatus. The assist system has been evaluated for long-term circulatory assistance in a series of ten calves. The assist pump was placed in the paracorporeal position. The longest period of continuous pumping was over eight months. The last four calves have had synchronized assist pumping which has permitted prolonged ventricular decompression and assist pump flow rates as high as 10 L/min. Three of these four calves had no evidence of thromboemboli. Additional animal studies will be required before clinical use of such an assist pump system can be safely undertaken.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1344113PMC
http://dx.doi.org/10.1097/00000658-197410000-00006DOI Listing

Publication Analysis

Top Keywords

assist pump
12
left ventricular
8
assist system
8
assist
7
pump
5
complete left
4
ventricular bypass
4
bypass paracorporeal
4
paracorporeal pump
4
pump design
4

Similar Publications

Background: Immune checkpoint inhibitors (ICIs) are effective antineoplastic agents but can cause adverse effects in many organ systems. Cardiovascular toxicities include arrhythmias, myocarditis, heart failure, takotsubo syndrome, pericarditis, coronary artery disease, and vasculitis.

Case Summary: A 66-year-old woman with Stage 3C2 endometrial carcinoma presented for her second cycle of pembrolizumab, carboplatin, and paclitaxel.

View Article and Find Full Text PDF

Background: Postcardiotomy cardiogenic shock (PCCS) in cardiac surgery is associated with a high rate of morbidity and mortality. Beside other therapeutic measures (e.g.

View Article and Find Full Text PDF

Purpose: Despite significant improvements in the design and performance of continuous flow left ventricular assist devices (CFLVADs), one of the most important reasons hampering further penetration of this technology is the occurrence of adverse events, especially strokes. One of the well-known risk factors for strokes is hypertension which is particularly common in patients undergoing a CFLVAD implant. While the device is implanted in the heart, strokes happen due to pathology in the brain and we hypothesised that modelling the blood flow in the circle of Willis might shed light on the causation of strokes in this situation.

View Article and Find Full Text PDF

The intra-aortic balloon pump (IABP) is a widely-used mechanical circulatory support device that enhances hemodynamics in patients with heart conditions. Although the IABP is a common clinical tool, its effectiveness in enhancing outcomes for patients with acute myocardial infarction and cardiogenic shock remains disputed. This study aimed to assess the effectiveness of intra-aortic dual-balloon pump (IADBP) and its impact on aortic hemodynamics compared with an IABP.

View Article and Find Full Text PDF

Acute myocardial infarction-related cardiogenic shock (AMI-CS) is a severe, life-threatening condition characterised by inadequate tissue perfusion due to the heart's inability to pump blood effectively. The pathophysiology of AMI-CS usually arises from the sudden loss of myocardial contractility, leading to a decrease in cardiac output and systemic hypoperfusion. In approximately 90% of AMI-CS cases, the left ventricle is the primary site of dysfunction.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!