Download full-text PDF |
Source |
---|
Sci Rep
December 2024
Department of Diagnostic Radiology, Dalhousie University, Halifax, Canada.
The goal of this study was to determine how radiologists' rating of image quality when using 0.5T Magnetic Resonance Imaging (MRI) compares to Computed Tomography (CT) for visualization of pathology and evaluation of specific anatomic regions within the paranasal sinuses. 42 patients with clinical CT scans opted to have a 0.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Oral and Maxillofacial Surgery, Yonsei University College of Dentistry, Gangnam Severance Hospital, 211 Eonju-ro, Gangnam-gu, Seoul, 06273, Republic of Korea.
This study aimed to investigate the cutoff values of standardized uptake values (SUVs) and their accuracy using single-photon emission computed tomography-computed tomography (SPECT-CT) for temporomandibular joint (TMJ) osteoarthritis (OA) based on magnetic resonance imaging (MRI) and clinical examination. We included 106 joints of 53 patients with TMJ OA. SUVmax and SUVpeak of each TMJ was measured.
View Article and Find Full Text PDFJ Antimicrob Chemother
December 2024
Food and Veterinary Institute Oldenburg, Lower Saxony State Office for Consumer Protection and Food Safety (LAVES), Oldenburg, Germany.
Antimicrobial susceptibility testing (AST) in the veterinary sector by broth microdilution is mainly based on commercially available microtitre plates with specific panels. A critical review of commercially available microtitre panels identified AST panels that fulfil the requirements for obtaining reliable AST results by covering the necessary antimicrobial concentrations for both clinical breakpoints as well as quality control (QC) ranges for approved QC strains. However, there are AST panels in which these prerequisites are only in part fulfilled, and some AST panels that do not fulfil the aforementioned criteria at all.
View Article and Find Full Text PDFClin Transplant
January 2025
Glickman Urological & Kidney Institute, Cleveland Clinic, Cleveland, Ohio, USA.
Background: Enhanced recovery after surgery (ERAS) protocols have gained widespread acceptance as a means to enhance surgical outcomes. However, the intricate care required for kidney transplant recipients has not yet led to the establishment of a universally recognized and dependable ERAS protocol for kidney transplantation.
Objective: We devised a customized ERAS protocol to determine its effectiveness in improving surgical and postoperative outcomes among kidney transplant recipients.
J Am Geriatr Soc
December 2024
Department of Public Health and Primary Care, KU Leuven, Leuven, Belgium.
Background: Frailty screening instruments are increasingly studied as risk predictors for adverse postoperative outcomes. However, because of the lack of comparative research, it is unclear which screening instrument performs best. This study therefore compared the diagnostic accuracy of seven frailty screening instruments for adverse postoperative outcomes in patients aged ≥70 years undergoing colorectal surgery.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!