A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Relationship between frequency dependence of lung compliance and distribution of ventilation. | LitMetric

The previously demonstrated empirical association between frequency dependence of lung compliance and distribution of ventilation, the latter determined by the N(2) washout technique, was confirmed by establishing a mathematical link between the two tests. By assuming a two-compartment system with known compliances and making corrections for Pendelluft and common dead space mixing effects, the ratio of dynamic to static compliance (C(dyn)/C(st)) for any respiratory frequency can be calculated from the compartmental analysis of the N(2) washout at a single respiratory frequency. By using these equations, a good correlation was found between calculated and measured C(dyn)/C(st) in dogs with artificially induced bronchial obstruction and in young smokers or young nonsmokers after carbachol inhalation. A two-compartment N(2) washout was demonstrated in 10 young healthy smokers at one or two respiratory frequencies whereas all 10 normal controls showed a single exponential curve. These findings indicate that the non-invasive N(2) washout test is capable of predicting C(dyn)/C(st) and at the same time gives a direct measure of gas distribution. Further, it appears to be a highly sensitive method for the detection of "small airway disease."

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC301667PMC
http://dx.doi.org/10.1172/JCI107863DOI Listing

Publication Analysis

Top Keywords

frequency dependence
8
dependence lung
8
lung compliance
8
compliance distribution
8
distribution ventilation
8
respiratory frequency
8
relationship frequency
4
ventilation demonstrated
4
demonstrated empirical
4
empirical association
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!