One donor can provide separate platelet and granulocyte-platelet units that have the potential to fulfill the needs of two recipients. Combined platelet and leukapheresis were performed in the presence of hyddroxyethyl starch and citrate employing the Haemonetics Model 30 Blood Separator. Platelets and granulocytes were separated subsequently by centrifugation and two individual units were prepared for transfusion. The platelet units contained a mean of 4.4 x 10(11) platelets/unit and were nearly devoid of leukocytes. The combined granulocyte-platelet units contained a mean of 7.38 x 10(9) neutrophils/unit and 3.06 x 10(11) platelets/unit. Thus two separate units containing sufficient numbers of cells for transfusion can be obtained from pheresis of one donor.

Download full-text PDF

Source
http://dx.doi.org/10.1046/j.1537-2995.1979.19279160296.xDOI Listing

Publication Analysis

Top Keywords

granulocyte-platelet units
12
separate platelet
8
platelet granulocyte-platelet
8
units contained
8
1011 platelets/unit
8
units
6
combined platelet-leukapheresis
4
platelet-leukapheresis technique
4
technique preparing
4
preparing separate
4

Similar Publications

The hematologic abnormalities of SIV and HIV are well described, although the mechanisms that lead to hematopoietic dysfunction are yet to be fully defined. A number of growth factors and cytokines have been used to induce the differentiation, maturation, and proliferation of appropriate lineages, with the aim that such therapy will lead to functional hematopoietic reconstitution. Within this context, some cytokines have been shown to influence HIV and SIV replication in vitro and, in selected cases, in vivo.

View Article and Find Full Text PDF

A paired prospective study was performed to compare the in vitro storage characteristics and in vivo kinetics of platelets stored in granulocyte-platelet concentrates prepared by apheresis with platelets prepared from whole blood. Platelet and granulocyte-platelet concentrates were collected from five healthy volunteer autologous donors and stored for 16 to 18 hours at 20 to 24 degrees C with and without agitation, respectively. After storage, pH, platelet count, percent release of beta-thromboglobulin, morphologic score, and percent osmotic recovery were measured.

View Article and Find Full Text PDF

This study was undertaken to document the incidence of immediate, nonhemolytic transfusion reactions and to identify a technique or set of techniques that would best identify the different causes of these reactions. A variety of tests were employed to detect lymphocyte, granulocyte, platelet and anti-IgA antibodies. During this study 26,318 units of blood components were transfused on 5,030 occasions.

View Article and Find Full Text PDF

One donor can provide separate platelet and granulocyte-platelet units that have the potential to fulfill the needs of two recipients. Combined platelet and leukapheresis were performed in the presence of hyddroxyethyl starch and citrate employing the Haemonetics Model 30 Blood Separator. Platelets and granulocytes were separated subsequently by centrifugation and two individual units were prepared for transfusion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!