Download full-text PDF

Source

Publication Analysis

Top Keywords

[assessment ventricular
4
ventricular hypertrophy
4
hypertrophy computer
4
computer analysis
4
analysis vectorcardiogram]
4
[assessment
1
hypertrophy
1
computer
1
analysis
1
vectorcardiogram]
1

Similar Publications

Background: Ventricular arrhythmias (VAs) frequently occur in the acute phase of myocarditis. Possible arrhythmic recurrences and the risk of sudden cardiac death (SCD) in this setting are reasons for concern, and limited data have been published to guide clinical management of these patients. The aim of the present paper is to report the incidence of major arrhythmic events, defined as sustained VA, SCD and appropriate implantable cardiac-defibrillator (ICD) treatment, in patients with acute myocarditis and ventricular arrhythmic phenotype.

View Article and Find Full Text PDF

Objective: Elevated intracranial pressure (ICP), a common complication in traumatic brain injuries (TBI), can lead to optic nerve sheath diameter (ONSD) enlargement and flow spectrum changes from the internal carotid artery (ICA) to middle cerebral artery (MCA). This study will investigate the use of Cervical-Cerebral Arterial Ultrasound (CCAU) for non-invasive ICP assessment and evaluating the related indices' clinical utility in TBI patients with decompressive craniotomy (DC).

Methods: ONSD and flow spectrum changes were measured within 24 h after DC in 106 patients via ultrasonic ONSD measurement and CCAU, simultaneously.

View Article and Find Full Text PDF

Introduction: The severity of mitral stenosis (MS) is commonly assessed using mitral valve area (MVA) measured with transthoracic echocardiography (TTE). The dimensionless index (DI) of mitral valve (MV) was recently studied in degenerative MS. We evaluated DI MV in rheumatic MS and studied its relationship with clinical outcomes.

View Article and Find Full Text PDF

Thoracoabdominal aortic aneurysm (TAAA) repair remains one of the most challenging procedures and is associated with high mortality and complication rates. Careful consideration of the surgical strategy is essential, particularly in cases involving extensive replacement and high-risk patients. A 61-year-old man with a 55-mm TAAA was referred for surgical treatment.

View Article and Find Full Text PDF

Clinical utility of myocardial work assessment in arterial hypertension and cardiovascular diseases.

Minerva Cardiol Angiol

January 2025

Department of Anatomy and Embryology, Faculty of Health, Medicine and Life Sciences, Maastricht University, Maastricht, the Netherlands.

In clinical practice, ventricular ejection fraction (EF) and global longitudinal strain (GLS) are the most often used parameters for evaluating left ventricular systolic function, despite the impact that variable loading conditions have. Alternatively, the myocardial efficiency (ME) of the heart, encompassing cardiac energy formation and dissipation, along with myocardial oxygen consumption (MVO2), is a useful surrogate for assessing myocardial work (MW), a parameter correlated with the pressure-strain loop (PSL), arterial pressure, and cardiac output (CO). This refinement proves especially practical in defining cardiac work across various clinical contexts, including arterial hypertension and heart failure (HF), the primary conditions associated with cardiovascular mortality.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!