A water-equivalent plastic material RW-1, in the form of thin foils as well as of thicker sheets, has been produced by melting powdered polyethylene together with CaCO3 and MgO. The mixture has been developed in a three-step procedure, starting with provisional mixtures and using data from their measured attenuation curves to determine the final composition. The attenuation curves of RW-1 and of water, as well as their backscatter factors, are in excellent agreement for x-ray tube voltages from 10 to 100 kV.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/30/11/002DOI Listing

Publication Analysis

Top Keywords

tube voltages
8
voltages 100
8
attenuation curves
8
polyethylene-based water-equivalent
4
water-equivalent phantom
4
phantom material
4
material x-ray
4
x-ray dosimetry
4
dosimetry tube
4
100 water-equivalent
4

Similar Publications

Dynamic Digital Radiography (DDR) in the Diagnosis of a Diaphragm Dysfunction.

Diagnostics (Basel)

December 2024

Postgraduation School in Radiodiagnostics, Università degli Studi di Milano, Via Festa del Perdono 7, 20122 Milan, Italy.

Dynamic digital radiography (DDR) is a recent imaging technique that allows for real-time visualization of thoracic and pulmonary movement in synchronization with the breathing cycle, providing useful clinical information. A 46-year-old male, a former smoker, was evaluated for unexplained dyspnea and reduced exercise tolerance. His medical history included a SARS-CoV-2 infection in 2021.

View Article and Find Full Text PDF

Polymer nanocomposites have been investigated as lightweight and suitable alternatives to lead-based clothing. The present study aims to fabricate flexible, lead-free, X-ray-shielding composites using a polyvinyl chloride (PVC) matrix and different nanostructures. Four different nanostructures containing impure tungsten oxide, tungsten oxide (WO), barium tungstate (BaWO), and bismuth tungstate (BiWO) were synthesized through various methods.

View Article and Find Full Text PDF

Purpose: With the widespread introduction of dual energy computed tomography (DECT), applications utilizing the spectral information to perform material decomposition became available. Among these, a popular application is to decompose contrast-enhanced CT images into virtual non-contrast (VNC) or virtual non-iodine images and into iodine maps. In 2021, photon-counting CT (PCCT) was introduced, which is another spectral CT modality.

View Article and Find Full Text PDF

Establishment of Local Diagnostic Reference Levels for Head CT Imaging in the Madina Region, Saudi Arabia.

Diagnostics (Basel)

December 2024

Medical Diagnostic Imaging Department, College of Health Science, University of Sharjah, Sharjah 27272, United Arab Emirates.

: Computed Tomography (CT) is crucial in medical diagnosis, particularly for head examinations. Diagnostic Reference Levels (DRLs) are pivotal in balancing diagnostic efficacy with radiation safety. International organizations such as the International Atomic Energy Agency (IAEA) and the International Commission on Radiological Protection (ICRP) provide guidelines for establishing DRLs, emphasizing their importance in optimizing radiation doses.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigated the noise reduction capabilities of a photon-counting detector (PCD) in computed tomography (CT) using a model-based iterative reconstruction algorithm (QIR).
  • Forty repeated scans were conducted on a water phantom and compared with a conventional energy-integrating detector (EID) to assess noise characteristics.
  • Results showed that PCD-CT significantly reduced noise levels and improved image uniformity, demonstrating the effectiveness of QIR in decreasing noise without altering the overall distribution of noise values.
View Article and Find Full Text PDF