A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pilocarpine concentrations in aqueous humor following single drop application. I. Effect of soft contact lenses. | LitMetric

AI Article Synopsis

  • The study investigated the effects of pilocarpine on rabbits, measuring drug levels in the aqueous humor and observing changes in pupil size and intraocular pressure (IOP) after single drop instillation.
  • Higher concentrations of pilocarpine led to increased drug levels, but this increase wasn't consistently significant nor proportional to the dosage.
  • The presence of contact lenses influenced pilocarpine levels over time, showing reduced concentrations at two hours, but did not affect the overall miosis or IOP measurements during the study.

Article Abstract

Following single drop instillation of pilocarpine, drug levels in individual aqueous humor samples of rabbits were determined by high-performance liquid chromatography and correlated with changes in pupillary diameter and intraocular pressure (IOP). Application of higher concentrations of pilocarpine resulted in higher drug levels but these differences were neither statistically significant nor consistently proportional to the strength applied. Maximum miosis occurred between 30 and 60 minutes and the maximum fall in IOP occurred between 1 and 2 hours. The influence of contact lenses with varying water content and thickness upon intraocular penetration of pilocarpine was studied. Contact lenses did not affect 30-minute concentrations of pilocarpine in aqueous humor. Although two-hour levels were significantly lower with contact lenses, miosis and IOP at these time periods were comparable with and without lenses. Neither water content nor thickness appreciably influenced miosis and IOP.

Download full-text PDF

Source
http://dx.doi.org/10.3109/02713688509003349DOI Listing

Publication Analysis

Top Keywords

contact lenses
16
aqueous humor
12
single drop
8
drug levels
8
concentrations pilocarpine
8
water content
8
content thickness
8
miosis iop
8
pilocarpine
5
lenses
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!