Emphysematous pyelonephritis complicated by a perirenal hematoma was diagnosed by computerized tomography. The computerized tomography scan was normal 3 months previously. Computerized tomography may be the procedure of choice to diagnose and stage emphysematous pyelonephritis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0022-5347(17)47538-0DOI Listing

Publication Analysis

Top Keywords

computerized tomography
16
emphysematous pyelonephritis
12
pyelonephritis complicated
8
diagnosed computerized
8
tomography scan
8
complicated hemorrhage
4
hemorrhage diagnosed
4
computerized
4
tomography
4
scan emphysematous
4

Similar Publications

Purpose: To investigate the anatomical variations and measure the distances between surgically relevant structures in the maxilla associated with Le Fort I osteotomy in patients with maxillary canting using cone beam computed tomography (CBCT).

Methods: CBCT scans of 63 patients (21 males and 42 females) with maxillary canting who were indicated for orthognathic surgical planning were retrospectively investigated and analyzed. The distances of the relevant anatomical structures, including the descending palatine artery, pterygomaxillary junction, infraorbital foramen, and nasolacrimal duct opening, were measured with the key anatomical landmarks to evaluate their variations.

View Article and Find Full Text PDF

Objectives: To characterize the radiological findings of desmoid-type fibromatosis (DF).

Methods: This two-institution retrospective study included 152 patients with pathologically confirmed DF who underwent computed tomography (CT), magnetic resonance imaging (MRI), or 18F-fluorodeoxyglucose-positron emission tomography (FDG-PET)/CT between January 2001 and February 2024. Two board-certified radiologists independently evaluated the CT, MRI, and FDG-PET/CT findings, and a third board-certified radiologist resolved discrepancies.

View Article and Find Full Text PDF

Purpose: The study aimed to examine the usefulness of a novel density measurement drill for evaluating cancellous bone density by examining the correlation between computed tomography (CT)-based Misch bone density classification and drilling torque value.

Methods: Bovine ribs were used as the drilling sites for implant placement. Multidetector CT (MDCT) was performed after contrast materials were attached to the drilling sites.

View Article and Find Full Text PDF

Objectives: Sharing micro-computed tomographic (μCT) scans of teeth increases data accessibility and reduces the need for repeated scans of any given specimen. However, the use of the same TIFF stacks or DICOMs by multiple individuals has the potential to introduce new sources of error. Here, we explore whether use of the same μCT scans by different persons produces comparable results.

View Article and Find Full Text PDF

Background: In X-ray computed tomography (CT), metal-induced beam hardening artifacts arise from the complex interactions between polychromatic X-ray beams and metallic objects, leading to degraded image quality and impeding accurate diagnosis. A previously proposed metal-induced beam hardening correction (MBHC) method provides a theoretical framework for addressing nonlinear artifacts through mathematical analysis, with its effectiveness demonstrated by numerical simulations and phantom experiments. However, in practical applications, this method relies on precise segmentation of highly attenuating materials and parameter estimations, which limit its ability to fully correct artifacts caused by the intricate interactions between metals and other dense materials, such as bone or teeth.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!