Among 111 hearts with so-called "isolated" ventricular septal defect, 18 specimens were found to have a subaortic perimembranous defect with an overriding aortic valve but without pulmonary stenosis. The ventricular architecture was characterized by several abnormalities. A constant finding was the wide right ventricular outflow tract. The outlet septum had its normal continuity with the septomarginal trabecula, but its parietal extension was located relatively far anteriorly. Part of the aortic valve thus inserted to the right ventricular component of the ventriculo-infundibular fold in the gap between the outlet septum and the tricuspid valve. Left ventricular abnormalities comprised mitral valve anomalies in all cases. There was an anteroseptal twist (leftward thickening of the anterior part of the ventricular septum) in 16 cases. A bicuspid aortic valve and/or malformed cusps were observed in 4 cases. Because of the linking phenomenon of aortic override, we also examined 10 hearts with tetralogy of Fallot and, in the latter, such abnormalities were not found. Our observations indicate that this seemingly simple type of defect is part of a complex malformation involving both septation and valve formation. Awareness of the existence of the architectural abnormalities might make them accessible for echocardiographic diagnosis. It was noteworthy that 11 of the 18 patients had chromosomal abnormalities, 9 of them presenting with trisomy-18.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/0167-5273(85)90032-4 | DOI Listing |
Kardiol Pol
January 2025
3rd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia in Katowice, Silesian Center for Heart Diseases, Zabrze, Poland.
Am J Ther
January 2025
Department of Interventional Cardiology, Queen Elizabeth Hospital, Birmingham, United Kingdom.
Catheter Cardiovasc Interv
January 2025
Department of Cardiology, Maastricht University Medical Centre, Maastricht, The Netherlands.
Background: Conduction disturbances are common after transcatheter aortic valve implantation (TAVI) and frequently require permanent pacemaker implantation (PPI). Data regarding its impact on mortality and morbidity are conflicting. This study aims to assess the impact of PPI before or within 30 days after TAVI on mortality and health-related Quality of Life (QoL) during the first year after TAVI.
View Article and Find Full Text PDFJ Int Med Res
January 2025
Colombo South Teaching Hospital, Colombo, Sri Lanka.
A 70-year-old man developed intermittent fever with chills, severe anorexia, generalized weakness, and mild exertional difficulty in breathing following posterior chamber intraocular lens replacement surgery for a mature white cataract in the left eye. Laboratory tests revealed persistent negative blood cultures, normocytic and normochromic anemia, neutrophilia, and elevated inflammatory markers despite multiple courses of antibiotics. All other investigations conducted to identify the cause of prolonged fever, including transthoracic echocardiography, were negative.
View Article and Find Full Text PDFEur Heart J Case Rep
January 2025
Division of Cardiology, Department of Medicine, Kindai University Faculty of Medicine, 377-2 Ohno-Higashi, Osakasayama, Osaka 589-8511, Japan.
Background: The initial outcomes of transcatheter aortic valve replacement in patients with left ventricular outflow tract calcification are poor. Furthermore, balloon-expandable transcatheter aortic valve replacement is associated with an increased risk of annular rupture, and self-expandable transcatheter aortic valve replacement is associated with worse post-operative residual paravalvular leakage grades. Therefore, developing an optimal method for transcatheter aortic valve replacement for patients with left ventricular outflow tract calcification is desirable.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!