Artifacts related to barium flow during double-contrast esophagography may obscure mucosal surface details. Double-contrast esophagograms with flow artifacts of 35 patients were evaluated to determine the effect on radiographic interpretation and to assess the method of examination. Initial radiographs obtained during swallowing of barium were compared with those obtained after a slight delay while patients repeatedly dry swallowed. When severe surface flow artifacts were present, the extent of mucosal disease was underestimated in all cases. Mild surface flow artifacts interfered with the demonstration of the reticular pattern of Barrett esophagus, and luminal flow artifacts caused misinterpretation. The demonstration of strictures was unaffected by flow artifacts. This study suggests that the dry swallowing maneuver and some delay improve depiction of esophageal surface details on double-contrast radiographs and obviate interpretive error from barium flow artifacts.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1148/radiology.157.2.4048465 | DOI Listing |
Biomed Opt Express
January 2025
Faculty of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa 3200003, Israel.
In fiber-based confocal microscopy, using two separate fibers for illumination and collection enables the use of a few-mode fiber to achieve an effect similar to opening the pinhole in a conventional confocal microscope. In some Fourier-domain applications, however, or when a spectral measurement is involved, the coherent light detection would lead to noticeable spectral modulation artifacts that result from differential mode delay, an effect caused by the multimode propagation in the collection fiber. After eliminating these artifacts by using mode-dependent polarization control, we demonstrate effective spectrally encoded imaging with improved signal efficiency and lower speckle noise, and only a minor, negligible reduction in lateral and axial resolutions.
View Article and Find Full Text PDFCornea
January 2025
Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA.
Purpose: To report on optical coherence tomography angiography (OCTA) in patients with a type 1 Boston keratoprosthesis (KPro) and determine its feasibility through assessment of imaging artifacts.
Methods: KPro and non-KPro subjects were matched for age, gender, and glaucoma diagnosis. OCTA images of the peripapillary optic nerve were obtained, reviewed by 2 readers masked to the diagnosis for artifacts and usability, and used for microvascular measurements.
Cureus
December 2024
Department of Neurological Surgery, Ryofukai Satoh Neurosurgical Hospital, Fukuyama, Hiroshima, JPN.
Coil embolization of cerebral aneurysms often encounters challenges in achieving complete filling of the aneurysm sac due to complex shapes and hemodynamic factors, frequently resulting in the formation of a residual cavity (RC) at the aneurysm neck. The hemodynamic mechanisms underlying RC formation and growth, however, remain poorly understood. Computational fluid dynamics (CFD) analysis, combined with silent MRA free from contrast agents and metal artifacts, offers a promising approach to elucidate these mechanisms, potentially enhancing the clinical management of cerebral aneurysms post-coiling.
View Article and Find Full Text PDFWorld J Pediatr Congenit Heart Surg
January 2025
Department of Pediatrics, Inova Health System, Falls Church, VA, USA.
Pulmonary atresia with ventricular septal defect (PA-VSD) is usually diagnosed by transthoracic or fetal echocardiography, with the prenatal diagnosis being feasible and accurate if fetal cardiology services are available. The limitations of transthoracic echocardiography (TTE) in the evaluation of PA-VSD include the complete evaluation of the pulmonary arteries and patent ductus arteriosus, quantitative evaluation of the right ventricle size and function, and delineation of associated cardiac anomalies such as coronary artery anomalies, anomalies of systemic or pulmonary venous return, and complex arch anomalies. Echocardiography also has limitations in evaluating hemodynamics such as flow volumes, shunts, and regurgitant fraction.
View Article and Find Full Text PDFMagn Reson Med
January 2025
Department of Radiology & Nuclear Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
Purpose: To correct maternal breathing and fetal bulk motion during fetal 4D flow MRI.
Methods: A Doppler-ultrasound fetal cardiac-gated free-running 4D flow acquisition was corrected post hoc for maternal respiratory and fetal bulk motion in separate automated steps, with optional manual intervention to assess and limit fetal motion artifacts. Compressed-sensing reconstruction with a data outlier rejection algorithm was adapted from previous work.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!