Download full-text PDF |
Source |
---|
Indian J Nucl Med
November 2024
Center for Research and Production of Radioisotopes, Dalat Nuclear Research Institute, Vietnam Atomic Energy Institute (VINATOM), Da Lat City, Lam Dong Province, Vietnam.
Aims: This study aimed to evaluate the principal technical characteristics of a well-type gas-filled ionization chamber dose calibrator used in measuring radiopharmaceutical activity, namely accuracy, repeatability, and linearity. Furthermore, this work also explored the correlation between the device's response and the position and volume of the radiopharmaceutical I-131.
Materials And Methods: Experimental measurements were conducted on the ATOMLAB 500 dose calibrator using NIST traceable Cs-137 source to determine the accuracy and repeatability.
Indian J Psychiatry
November 2024
Department of Psychiatry, All India Institute of Medical Sciences, New Delhi, India.
Background: Functional near-infrared spectroscopy (fNIRS) is being increasingly utilized to visualize the brain areas involved in cognitive activity to understand the human brain better. Its portability and easy setup give it an advantage over other functional brain imaging tools. The current study utilizes fNIRS while performing a Stroop test, which is commonly used to assess the impairment of information selection in depression.
View Article and Find Full Text PDFMagn Reson Med
January 2025
Department of Radiology & Nuclear Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
Purpose: To correct maternal breathing and fetal bulk motion during fetal 4D flow MRI.
Methods: A Doppler-ultrasound fetal cardiac-gated free-running 4D flow acquisition was corrected post hoc for maternal respiratory and fetal bulk motion in separate automated steps, with optional manual intervention to assess and limit fetal motion artifacts. Compressed-sensing reconstruction with a data outlier rejection algorithm was adapted from previous work.
Int J Retina Vitreous
January 2025
Eye Clinic, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, 25121, Brescia, Italy.
Background: To analyse the effect of suprachoroidal injection (SChI) of triamcinolone acetonide (TA) on macular thickness (CRT), ectopic inner foveal layer thickness (EIFL-T) and best corrected visual acuity (BCVA) in pseudophakic patients undergoing vitrectomy for epiretinal membrane (iERM) compared to intravitreal injection of TA (IVTA).
Methods: Prospective matched comparison of patients undergoing vitrectomy for Govetto stage 3 and 4 iERM. 25 eyes receiving IVTA (G-1) were compared to 23 eyes receiving SChI-TA (G-2) during vitrectomy.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!