Binding of peanut agglutinin (PNA) to normal human peripheral blood mononuclear cells was analyzed on a cell sorter, and compared to the binding of the monocyte specific monoclonal antibodies Mac-1 and Leu-M3. Each of the reagents labeled 9-11% of the mononuclear cells and similar binding patterns were observed. Of the PNA+ cells, 67% adhered to plastic petri dishes, whereas 76% of Mac-1+ cells were adherent. No competition for binding was observed between PNA and Mac-1 on the one hand, or PNA and Leu-M3 on the other. In double staining experiments, about 10% of the cells, comprising 80% of the monocytes, were PNA+ Leu-M3+. Our results show that PNA can serve for the identification and enumeration of monocytes in human peripheral blood.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0022-1759(85)90117-6DOI Listing

Publication Analysis

Top Keywords

enumeration monocytes
8
monocytes human
8
peanut agglutinin
8
human peripheral
8
peripheral blood
8
mononuclear cells
8
cells
5
detection enumeration
4
human blood
4
blood peanut
4

Similar Publications

The role of autophagy in host induced by infection of parasites of the Leishmania genus remains inadequately understood. Leishmania parasites modulate host macrophages to promote its survival by inducing autophagy response in the host cell. In this study, we conducted an investigation of L.

View Article and Find Full Text PDF

Here, we present a protocol for monitoring phagocytosis by M2-type macrophages using automated counting of phagocytic events with an imaging cytometer. We describe steps for isolating and differentiating peripheral blood mononuclear cell (PBMC)-derived monocytes into M2-like macrophages, preparing cancer cells expressing a green fluorescence marker, labeling with a pH-sensitive dye, and co-culturing with macrophages. We then outline procedures for enumerating phagocytic events using an imaging cytometer.

View Article and Find Full Text PDF

Low-dose pro-resolving mediators temporally reset the resolution response to microbial inflammation.

Mol Med

September 2024

Department of Anesthesiology, Perioperative and Pain Medicine, Center for Experimental Therapeutics and Reperfusion Injury, Mass General Brigham and Harvard Medical School, 60 Fenwood Rd., Hale Building for Transformative Medicine 3-016, Boston, MA, 02115, USA.

Background: Specialized pro-resolving mediators (SPMs) promote resolution of inflammation, clear infections and stimulate tissue regeneration. These include resolvins, protectins, and maresins. During self-resolving acute inflammation, SPMs are produced and have key functions activating endogenous resolution response for returning to homeostasis.

View Article and Find Full Text PDF

Performance evaluation of the digital morphology analyser Sysmex DI-60 for white blood cell differentials in abnormal samples.

Sci Rep

June 2024

National Clinical Research Center for Laboratory Medicine, Department of Laboratory Medicine, The First Hospital of China Medical University, Shenyang, 110001, Liaoning, China.

Sysmex DI-60 enumerates and classifies leukocytes. Limited research has evaluated the performance of Sysmex DI-60 in abnormal samples, and most focused on leukopenic samples. We evaluate the efficacy of DI-60 in determining white blood cell (WBC) differentials in normal and abnormal samples in different WBC count.

View Article and Find Full Text PDF

Within- and between-subject biological variation estimates for the enumeration of lymphocyte deep immunophenotyping and monocyte subsets.

Clin Chem Lab Med

October 2024

National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing, P.R. China.

Objectives: This study aimed to deliver biological variation (BV) estimates for 25 types of lymphocyte subpopulations subjected to deep immunophenotyping (memory T/B cells, regulatory T cells, etc.) and classical, intermediate, and nonclassical monocyte subsets based on the full spectrum flow cytometry (FS-FCM) and a Biological Variation Data Critical Appraisal Checklist (BIVAC) design.

Methods: Samples were collected biweekly from 60 healthy Chinese adults over 10 consecutive two-week periods.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!