Denoising complex-valued diffusion MR images using a two-step, nonlocal principal component analysis approach.

Magn Reson Med

Center for Magnetic Resonance Research, Radiology, Medical School, University of Minnesota, Minneapolis, Minnesota, USA.

Published: March 2025

Purpose: To propose a two-step, nonlocal principal component analysis (PCA) method and demonstrate its utility for denoising complex diffusion MR images with a few diffusion directions.

Methods: A two-step denoising pipeline was implemented to ensure accurate patch selection even with high noise levels and was coupled with data preprocessing for g-factor normalization and phase stabilization before data denoising with a nonlocal PCA algorithm. At the heart of our proposed pipeline was the use of a data-driven optimal shrinkage algorithm to manipulate the singular values in a way that would optimally estimate the noise-free signal. Our approach's denoising performances were evaluated using simulation and in vivo human data experiments. The results were compared with those obtained with existing local PCA-based methods.

Results: In both simulation and human data experiments, our approach substantially enhanced image quality relative to the noisy counterpart, yielding improved performances for estimation of relevant diffusion tensor imaging metrics. It also outperformed existing local PCA-based methods in reducing noise while preserving anatomic details. It also led to improved whole-brain tractography relative to the noisy counterpart.

Conclusion: The proposed denoising method has the utility for improving image quality for diffusion MRI with a few diffusion directions and is believed to benefit many applications, especially those aiming to achieve high-quality parametric mapping using only a few image volumes.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.30502DOI Listing

Publication Analysis

Top Keywords

diffusion images
8
two-step nonlocal
8
nonlocal principal
8
principal component
8
component analysis
8
human data
8
data experiments
8
existing local
8
local pca-based
8
image quality
8

Similar Publications

Denoising complex-valued diffusion MR images using a two-step, nonlocal principal component analysis approach.

Magn Reson Med

March 2025

Center for Magnetic Resonance Research, Radiology, Medical School, University of Minnesota, Minneapolis, Minnesota, USA.

Purpose: To propose a two-step, nonlocal principal component analysis (PCA) method and demonstrate its utility for denoising complex diffusion MR images with a few diffusion directions.

Methods: A two-step denoising pipeline was implemented to ensure accurate patch selection even with high noise levels and was coupled with data preprocessing for g-factor normalization and phase stabilization before data denoising with a nonlocal PCA algorithm. At the heart of our proposed pipeline was the use of a data-driven optimal shrinkage algorithm to manipulate the singular values in a way that would optimally estimate the noise-free signal.

View Article and Find Full Text PDF

In order to relate nanoparticle properties to function, fast and detailed particle characterization is needed. The ability to characterize nanoparticle samples using optical microscopy techniques has drastically improved over the past few decades; consequently, there are now numerous microscopy methods available for detailed characterization of particles with nanometric size. However, there is currently no "one size fits all" solution to the problem of nanoparticle characterization.

View Article and Find Full Text PDF

Advances in primary large B-cell lymphoma of immune-privileged sites.

Front Immunol

March 2025

Shanxi Bethune Hospital Cancer Center Lymphoma Department, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Third Hospital of Shanxi Medical University, Taiyuan, China.

Primary large B-cell lymphoma of immune-privileged sites (IP-LBCL) encompasses a spectrum of relatively rare aggressive B-cell lymphomas, such as primary central nervous system lymphoma (PCNSL), primary testicular large B-cell lymphoma (PTL), and primary vitreoretinal large B-cell lymphoma (PVRL). Macroscopically, the development of IPI-LBCL may be associated with the dysfunction of meningeal lymphatic vessels (mLVs) and the perivascular channel system formed by astrocytes. Microscopically, mutation in MYD88 and CD79B genes plays a pivotal role in the pathogenesis of IP-LBCL.

View Article and Find Full Text PDF

Head motion is a major source of image artifacts in head computed tomography (CT), degrading the image quality and impacting diagnosis. Image-domain-based motion correction is practical for routine use since it doesn't rely on hard-to-obtain CT projection data. However, existing convolutional neural network (CNN)-based methods tend to over-smooth images, particularly in cases of moderate to severe 3D motion artifacts.

View Article and Find Full Text PDF

Diffusion magnetic resonance imaging (dMRI) provides insight into the micro and macro-structure of the brain. Multi-shell multi-tissue constrained spherical deconvolution (MSMT-CSD) models the underlying local fiber orientation distributions (FODs) using the dMRI signal. While generally producing high-quality FODs, MSMT-CSD is a voxel-wise method that can be impacted by noise and produce erroneous FODs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!