Background: During the COVID-19 pandemic, severe respiratory failure is a life-threatening condition, and life-saving tracheal intubation is a high-risk aerosol- and droplet-generating procedure. It is crucial to protect healthcare workers without compromising patient safety during intubation. The use of personal protective equipment (PPE) and different types of laryngoscopes are measures to reduce the risk of infectious transmission that might impact the intubation process.
Objectives: This study aimed to evaluate the effects of different levels of PPE and types of laryngoscopes on the duration of the intubation process and its success rate.
Methods: We conducted an open, randomized, parallel clinical trial on non-COVID-19 adult patients scheduled for elective and emergency surgeries under general anesthesia from November 2021 to May 2022. Patients were divided into three groups: Group 1 was intubated using a video-guided laryngoscope with operators wearing level three PPE; group 2 was intubated using a direct laryngoscope with operators wearing level three PPE; and group 3 was intubated using a direct laryngoscope with operators wearing level two PPE. Intubation was performed by 2nd- and 3rd-year anesthesia residents.
Results: The duration of intubation varied significantly among the groups, with Group 1 taking the longest time (P = 0.046). Group 3 had a higher success rate for first-attempt intubation (P = 0.056).
Conclusions: The use of PPE and video-guided laryngoscopy had varying effects on the intubation procedure, with the most notable impact being on the overall length of intubation. Further research with a larger sample size is needed to validate these findings.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11895791 | PMC |
http://dx.doi.org/10.5812/aapm-148208 | DOI Listing |
J Anim Sci
March 2025
Department of Animal Sciences, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
Yellow mealworms (Tenebrio molitor) serve as an alternative protein source. Because the amino acid (AA) concentrations, AA digestibility, and protein quality of ingredients may vary depending on their husbandry, harvest and processing procedures, and other factors, each should be evaluated separately. The objective of this study was to measure the AA composition, AA digestibility, and protein quality of yellow mealworm-based ingredients using the precision-fed cecectomized rooster assay.
View Article and Find Full Text PDFFront Bioeng Biotechnol
February 2025
Department of Biomedical Engineering and Chemical Engineering, University of Texas at San Antonio, San Antonio, TX, United States.
Background: Inhalation injuries, caused by exposure to extreme heat and chemical irritants, lead to complications with speaking, swallowing, and breathing. This study investigates the effects of thermal injury and endotracheal tube (ETT) placement on the airway microbiome and inflammatory response. A secondary aim is to assess the impact of localized dexamethasone delivery via a drug-eluting ETT to reduce laryngeal scarring.
View Article and Find Full Text PDFAnesth Pain Med
October 2024
Anesthesiology Unit, Surgical Intensive Care and Pain Medicine Department, Faculty of Medicine, Tanta University, Tanta, Egypt.
Background: Modified rapid sequence intubation (RSI) is crucial in emergency surgery, particularly for patients with a full stomach, as it allows for the administration of general anesthesia (GA).
Objectives: This work aimed to evaluate mivacurium effectiveness and optimal dose in modified RSI.
Methods: This randomized double-blind study involved 100 patients, aged between 20 - 60 years, of both sexes, with the American Society of Anesthesiologists physical status classification of I - III, who were undergoing emergency surgery under GA.
Anesth Pain Med
August 2024
Department of Anesthesiology and Intensive Care, Cipto Mangunkusumo Hospital, Faculty of Medicine, Universitas Indonesia, Jakarta, Indonesia.
Background: During the COVID-19 pandemic, severe respiratory failure is a life-threatening condition, and life-saving tracheal intubation is a high-risk aerosol- and droplet-generating procedure. It is crucial to protect healthcare workers without compromising patient safety during intubation. The use of personal protective equipment (PPE) and different types of laryngoscopes are measures to reduce the risk of infectious transmission that might impact the intubation process.
View Article and Find Full Text PDFExpert Rev Med Devices
March 2025
Delhi Cancer Registry, DRBRAIRCH, AIIMS.
Objectives: LMA Gastro Airway (LGA) is an advanced airway device that allows simultaneous endoscopy through separate conduits and ventilation during endoscopic retrograde cholangiopancreatography (ERCP). It can be an alternative to an endotracheal tube (ETT) and potentially hasten recovery from general anesthesia(GA) by avoiding muscle relaxants. We aimed to compare LGA with ETT regarding recovery from anesthesia and adverse respiratory events.