This updated Heart Valve Collaboratory framework addresses the growing concern for transcatheter valve failure (TVF) following transcatheter aortic valve replacement (TAVR). With the increasing volume of redo-TAV and surgical TAV explantation, there is a critical need for standardized pathways and protocols for evaluating TVF using echocardiography and cardiac computed tomography (CT) angiography. This document clarifies prior definitions of bioprosthetic valve deterioration and bioprosthetic valve failure in a practical, imaging directed context for TAVR. It discusses various imaging modalities for diagnosing TVF, including echocardiography, cardiac CT angiography, cardiac magnetic resonance, and positron emission tomography/CT. Recommendations are provided on the systematic imaging for: 1) follow-up post-TAVR; 2) procedural planning for redo-TAV; and 3) post-redo-TAV, emphasizing the importance of regular monitoring and the need for comprehensive imaging data to optimize patient outcomes in the lifetime management of aortic valve disease.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacc.2024.12.017DOI Listing

Publication Analysis

Top Keywords

valve failure
12
transcatheter valve
8
aortic valve
8
echocardiography cardiac
8
bioprosthetic valve
8
valve
7
imaging
5
best practices
4
practices imaging
4
imaging transcatheter
4

Similar Publications

This updated Heart Valve Collaboratory framework addresses the growing concern for transcatheter valve failure (TVF) following transcatheter aortic valve replacement (TAVR). With the increasing volume of redo-TAV and surgical TAV explantation, there is a critical need for standardized pathways and protocols for evaluating TVF using echocardiography and cardiac computed tomography (CT) angiography. This document clarifies prior definitions of bioprosthetic valve deterioration and bioprosthetic valve failure in a practical, imaging directed context for TAVR.

View Article and Find Full Text PDF

Introduction: Newborn resuscitation is commonly performed in the presence of face mask leak. Leak is highly variable, pressure-dependent and often unrecognized. The effectiveness of resuscitation devices to deliver adequate inflations in the presence of leak is unknown.

View Article and Find Full Text PDF

Retrobulbar/intraconal tube placement in patients with glaucoma: Ahmed FP-7 and tube extender case series with 1 year follow-up.

Front Ophthalmol (Lausanne)

February 2025

Department of Ophthalmology, Advanced Eyecare of New York, New York, NY, United States.

Purpose: The Ahmed FP-7 valve is useful in the management of refractory glaucoma. However, this can often have ocular hypertensive phase and subconjunctival fibrosis that can lead to increased medication use and failure. We report how retrobulbar and intraconal plate placement with tube extension can avoid the ocular hypertensive phase, lower intraocular pressure, and reduce medication burden.

View Article and Find Full Text PDF

Background: Sutureless bioprosthetic valves (SBVs) are engineered to enable a less invasive surgical valve replacement procedure in patients at high surgical risk. Valve degeneration is a relatively common occurrence across all types of surgical valves, including SBVs. Valve-in-valve (ViV) procedures are increasingly becoming the preferred treatment for many cases of valve degeneration due to their minimally invasive nature and favourable long-term outcomes.

View Article and Find Full Text PDF

Cardiac damage after polytrauma: the role of systematic transthoracic echocardiography - a pilot study.

World J Emerg Surg

March 2025

Department of Trauma Surgery and Orthopedics, Goethe University Frankfurt, University Hospital, 60590, Frankfurt, Germany.

Background: Heart injuries following polytrauma (PT) are identified as a predictor of poor outcome. The diagnostic algorithm of cardiac damage after trauma consists of the systemic measurement of cardiac damage markers, a 3-channel ECG and if there are any suspicious findings, the conduction of a transthoracic echocardiography (TTE). The aim of this study was to implement a systematic analysis of cardiac function using TTE in PT-patients.

View Article and Find Full Text PDF