A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1057
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3175
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Evaluation of the Deodorizing Effect of an Electric Scalpels with a Smoke Evacuation System in Breast Surgery]. | LitMetric

Exposure to surgical smoke can cause discomfort owing to its odor. Although electric scalpels with smoke evacuation systems are recommended to reduce exposure to surgical smoke, few reports have focused on its effectiveness in odor reduction. This study aimed to evaluate the deodorizing effects of an electric scalpel with a smoke evacuation system during breast surgery. Using a portable odor sensor, we measured the odor levels during surgery in 2 groups: a conventional electric scalpel group(control group)and an electric scalpel with smoke evacuation system group(evacuation group). Analysis with the odor sensor showed that in the control group, odor levels increased by approximately 100-200 units from the baseline when the electric scalpel was used. In contrast, the evacuation group showed almost no increase from the baseline. Subjectively, the control group noticed visible smoke and odors, whereas the evacuation group did not experience any smoke or odors. The results indicated that using electrocautery devices with smoke evacuation systems not only provides a clear surgical field but also has a high deodorizing effect.

Download full-text PDF

Source

Publication Analysis

Top Keywords

smoke evacuation
20
electric scalpel
16
evacuation system
12
smoke
9
electric scalpels
8
scalpels smoke
8
system breast
8
exposure surgical
8
surgical smoke
8
evacuation systems
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!