Positron emission tomography (PET) is a valuable tool for diagnosing malignant tumors. Intraoperative PET imaging is expected to allow the more accurate localization of tumors that need resections. However, conventional devices feature a large detector ring that obstructs surgical procedures, preventing their intraoperative application. This paper proposes a new PET device, Scratch-PET, for image-guided tumor resection. The key feature of Scratch-PET is its use of a hand-held detector to scan the surgical field, ensuring open space for surgery while measuring annihilation radiation with a fixed detector array placed below the patient. We developed a prototype device using two detectors: the hand-held detector and a fixed detector, to demonstrate the feasibility of the proposed concept. Both detectors consisted of 16 × 16 arrays of lutetium yttrium orthosilicates (3 × 3 × 15 mm) coupled one-to-one with 16 × 16 silicon photomultiplier arrays. The position and orientation of the hand-held detector are tracked using an optical tracking sensor that detects attached markers. We measured a Na multi-rod phantom and two Na point sources separately for 180 s while moving the hand-held detector. The rod diameters were 6.0, 5.0, 4.0, 3.0, 2.2, and 1.6 mm. Each point source was placed at the field-of-view center and 35 mm off-center which was outside the sensitive area when the hand-held detector was positioned facing the fixed detector. The 2.2 mm rods were partially resolved, and both point sources were successfully visualized. The potential of the proposed device to visualize small tumors was validated.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s12194-025-00889-z | DOI Listing |
Radiol Phys Technol
March 2025
Center for Frontier Medical Engineering, Chiba University, Chiba, Japan.
Positron emission tomography (PET) is a valuable tool for diagnosing malignant tumors. Intraoperative PET imaging is expected to allow the more accurate localization of tumors that need resections. However, conventional devices feature a large detector ring that obstructs surgical procedures, preventing their intraoperative application.
View Article and Find Full Text PDFAnal Chem
January 2025
State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China.
Thin-film fluorescent chemosensors, characterized by their tunable design, high selectivity, and exceptional sensitivity, hold significant promise for gas detection applications. However, the simultaneous realization of the 3S attributes (sensitivity, selectivity, and stability) remains a formidable challenge, particularly in the underexplored field of near-infrared (NIR) gas detection. In this work, we employ an acceptor-donor-acceptor (A-D-A) molecular design strategy to drive the development of an organic semiconductor fluorescent material with a progressive red shift in the emission wavelength.
View Article and Find Full Text PDFEnviron Monit Assess
November 2024
Faculty of Science, Tunis El Manar University, LR11RS23, 1006, Tunis, Tunisia.
To establish a radiological national reference for agricultural soil across Tunisian oases and assess the risk to human health associated with date consumption, with a focus on comparing the impact of traditional and modern fertilization, radiological parameters and activity levels of ⁶Ra, Th, and ⁰K were determined for 27 oases. These oases were located in three southern Tunisian governorates. The activity concentration of ⁶Ra, Th, and ⁰K was measured using a 3 × 3 inch NaI(Tl) scintillation detector, which was found to be 21.
View Article and Find Full Text PDFSpectrochim Acta A Mol Biomol Spectrosc
February 2025
Department of Electrical and Electronic Engineering, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh. Electronic address:
Anal Chem
September 2024
Clinical Study and Evidence Based Medicine Institute, Gansu Provincial People's Hospital, Lanzhou 730000, P.R. China.
Phenylketonuria (PKU) is one of the most common genetic metabolic diseases, especially among newborns. Traditional clinical examination of newborn blood samples for PKU is invasive, laborious, and limited to hospitals and healthcare facilities. We reported herein a SERS-based sensor array with three thiophenolic nanoreceptors built on a patterned nanorod vertical array for rapid and inexpensive detection of characteristic volatile biomarkers indicative of PKU in the urine and accurate classification of newborn baby patients all performed on a hand-held SERS spectrophotometer.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!