A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1057
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3175
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Trajectory- the unseen realm in a firing event: a novel and scientific approach in the identification of optimal recovery zones for gunshot residue micro traces. | LitMetric

Gunshot residue (GSR) particles, generated during firearm discharge, disperse in the surrounding environment according to physical laws governing the motion of particles. This study analyzes GSR distribution from 9 × 19 mm ammunition along the trajectory with a fixed target. GSR particle count follows a bell-shaped distribution, influenced by velocity, temperature, and burn rate. Understanding this pattern aids in modeling GSR dispersion based on muzzle-to-target distance, improving forensic analysis of shooting incidents. The kinematic behavior of GSR particles observed in this study facilitated the identification of the region exhibiting the highest deposition. The peak particle deposition was detected along the projectile trajectory, specifically at 100-130 cm from the muzzle end, in the direction of fire. This facilitated the identification of the distance at which the probability of obtaining maximum GSR particles is possible. This aids forensic investigations, providing insights into the trajectory, and identifying the potential region of maximum GSR deposition. A significant influence of distance on the number of GSR particle deposition was observed in the study. The study highlights the necessity of GSR collection along the trajectory, where retrieval probability is higher than at the muzzle or target. A methodology using the Trasoscan Laboratory Imaging System (TLIS) for GSR detection and counting is proposed. TLIS demonstrates potential as a primary imaging tool, with analytical data represented as particle frequency in the shooting vicinity. SEM analysis reveals significant deviations in GSR size distribution across muzzle, trajectory, and target, enhancing accuracy by identifying GSR-dense areas for more precise forensic conclusions. The largest GSR particles were recovered from the target distance (470-500 cm), suggesting surface modifications upon impact, which can be instrumental in estimating the shooting distance. The proposed approach could be implemented in current analytical pipelines or caseworks.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12024-025-00980-2DOI Listing

Publication Analysis

Top Keywords

gsr particles
16
gsr
12
gunshot residue
8
gsr particle
8
observed study
8
facilitated identification
8
particle deposition
8
maximum gsr
8
particles
5
trajectory
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!