Rotor attitude detection (RAD) is one of the key technologies to control permanent magnet spherical motors (PMSpM). This paper proposes an improved you only look once v8n (YOLOv8n) based RAD method for a PMSpM. The visual image datasets collection and annotation method are described, and three different visual feature objects are set for the RAD. To increase the real-time performance of the YOLOv8n algorithm, the backbone and head of the YOLOv8n network are improved by introducing the FasterNet and c2fFaster modules. PyTorch 2.0.1 and CUDA 11.8 with Python 3.11.4 are used to conduct the verification experiments. The models are trained on both the custom PMSpM datasets and the publicly available datasets COCO 2017. The verification shows that the inference time of the improved YOLOv8n algorithm can be as short as 4.31 ms for the PMSpM custom datasets on the basis of ensuring visual object detection accuracy. Thus, the performance of the improved YOLOv8n algorithm is significantly better than that of the YOLOv8n and the multiobject Kalman kernel correlation filter (MKKCF) algorithm. The PMSpM rotor attitude can be calculated using the positional relationships of three visual objects captured by a single monocular industrial camera. To verify the precision of the proposed RAD method, the contact RAD method is taken as the benchmark for a comparison between the MKKCF-based RAD method and the improved YOLOv8n-based RAD method. Typical PMSpM spatial motion experiments demonstrate that the proposed improved YOLOv8n-based RAD method achieves higher precision than the MKKCF-based visual RAD method.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0239142DOI Listing

Publication Analysis

Top Keywords

rad method
28
rotor attitude
12
yolov8n algorithm
12
rad
9
attitude detection
8
method
8
three visual
8
improved yolov8n
8
improved yolov8n-based
8
yolov8n-based rad
8

Similar Publications

Background: Kidney transplantation (KT) has dramatically improved the quality of life of patients with end-stage kidney disease. However, the incidence of opportunistic infections has also increased because of immunosuppression. A common infection after KT is cytomegalovirus (CMV).

View Article and Find Full Text PDF

Volumetric, Microfluidic Plasmonic RT-PCR.

Small Methods

March 2025

Department of Biomedical Engineering, Columbia University, New York, NY, 10027, USA.

Decentralized molecular detection of pathogens remains an important goal for public health. Although polymerase chain reaction (PCR) remains the gold-standard molecular detection method, thermocycling using Peltier heaters presents challenges in decentralized settings. Recent work has demonstrated plasmonic PCR, where nanomaterials on a surface or nanoparticles in solution heat upon stimulation by light, as a promising method for rapid thermocycling.

View Article and Find Full Text PDF

Rotor attitude detection (RAD) is one of the key technologies to control permanent magnet spherical motors (PMSpM). This paper proposes an improved you only look once v8n (YOLOv8n) based RAD method for a PMSpM. The visual image datasets collection and annotation method are described, and three different visual feature objects are set for the RAD.

View Article and Find Full Text PDF

Background: There is low-certainty evidence on the impact of extended pharmacological prophylaxis on venous thromboembolism-associated morbidity and mortality. The aim of this study was to determine the efficacy and safety of extended prophylaxis after major abdominopelvic surgery for the prevention of clinically relevant venous thromboembolism after hospital discharge.

Methods: CArdiovaSCulAr outcomes after major abDominal surgEry (CASCADE) was a prospective, international, cohort study into which consecutive adult patients undergoing major abdominopelvic surgery were enrolled (January-May 2022).

View Article and Find Full Text PDF

Introduction: Fetal hemoglobin (HbF) is known to cause method-specific interference in glycated hemoglobin A1c (HbA1c) measurement. Data on HbF interference, however, is currently either lacking for some platforms (eg, the Abbott Core Laboratory Alinity c and Beckman Coulter AU5800) or available only for HbF levels lower than the maximum claimed by the manufacturer (eg, Bio-Rad D-100).

Methods: We examined the effect of HbF interference on 7 HbA1c platforms using a series of spiked adult whole blood samples with increasing HbF levels (0% to 35%) and either low (approximately 5%) or high (approximately 9%) HbA1c levels, using isotope dilution mass spectrometry as a reference measurement procedure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!