A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1057
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3175
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Acurate Neo2 for valve-in-valve treatment of degenerated 3F Enable sutureless bioprosthetic valve in nonagenarian patient: a case report. | LitMetric

Background: Sutureless bioprosthetic valves (SBVs) are engineered to enable a less invasive surgical valve replacement procedure in patients at high surgical risk. Valve degeneration is a relatively common occurrence across all types of surgical valves, including SBVs. Valve-in-valve (ViV) procedures are increasingly becoming the preferred treatment for many cases of valve degeneration due to their minimally invasive nature and favourable long-term outcomes. However, the specific structural characteristics of SBVs present challenges for ViV procedures, and the evidence on this subject remains limited.

Case Summary: A 91-year-old man was admitted to our hospital presenting with dyspnoea due to severe aortic regurgitation in a degenerated 3F Enable sutureless valve. Valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) was successfully performed using a self-expanding Acurate Neo2 valve, yielding good haemodynamic results without overt interaction between the prosthesis. A 6-month follow-up echocardiogram confirmed excellent valve performance.

Discussion: ViV-TAVI is a well-established treatment for bioprosthetic valve failure in high-risk patients. However, sutureless valve degeneration presents a challenging scenario for ViV procedures, with only a limited number of cases performed using the Acurate platform. In this case, we demonstrated the technical feasibility of ViV using the Acurate system in a less explored surgical sutureless bioprosthesis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11895507PMC
http://dx.doi.org/10.1093/ehjcr/ytaf073DOI Listing

Publication Analysis

Top Keywords

valve degeneration
12
viv procedures
12
valve
10
acurate neo2
8
degenerated enable
8
enable sutureless
8
sutureless bioprosthetic
8
bioprosthetic valve
8
sutureless valve
8
sutureless
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!