Background: Retrograde superior ramus screw of pubis (SRSP) is a new kind of pelvic minimally invasive internal fixation apparatus developed by our team. The purpose of this study was to analyze the biomechanical stability of this new minimally invasive pelvic internal fixation device, and to provide this new device with theoretical basis for clinical application.

Methods: The Tile C1.3 pelvic fracture model was established. The posterior ring was fixed in the same way with two sacroiliac screws. And the anterior ring was fixed with SRSP, reconstruction plate, minimal invasive subcutaneous internal fixator (INFIX) and hollow screw respectively, to establish the finite element model of fracture-internal fixation. Finite element analysis was used to analyze the deformation and Von Mises(V-M) stress distribution of different kind of fixation under three kinds of stress conditions: vertical self-weight load, anterior-posterior(A-P) compression and lateral compression.

Results: Among the four-kind fixation models, all the maximum displacement of fracture site were significantly less than 2 cm, and the maximum V-M stress of internal fixation was lower than the yield stress of titanium metal (1050 MPa). The maximum displacement and V-M stress of total model/internal fixation in INFIX group were higher than those in the others under three stress conditions except for two cases, which were the maximum displacement of total model in SRSP group (0.26266 mm) under A-P compression and the maximum displacement of internal fixation in SRSP group (0.32588 mm) under lateral compression. The values of total model/internal fixation displacement and V-M stress distribution in SRSP group were similar to those of reconstructed plate group and hollow screw group. Furthermore, the stress distribution of SRSP group was more uniform from the stress nephogram.

Conclusion: All four kinds of internal fixation can effectively repair Tile C1.3 pelvic fractures. Also fracture-fixation pelvis model were basically restore the normal mechanical conduction path, rebuilding overall stability of the pelvic ring with good static mechanical stability. The stress distribution of fracture-internal fixation model in SRSP group was more uniform. Compared with INFIX group, SRSP group was more advantageous in preventing excessive displacement of the fracture site, loosening and deformation of the internal fixation, etc.

Download full-text PDF

Source
http://dx.doi.org/10.1186/s13018-025-05676-5DOI Listing

Publication Analysis

Top Keywords

internal fixation
24
srsp group
24
stress distribution
16
maximum displacement
16
finite element
12
fixation
12
v-m stress
12
stress
10
group
10
element analysis
8

Similar Publications

Background: Atypical Hangman's fractures may involve bilateral C2 pedicle fractures. Surgical fixation is often required to prevent instability and neurological impairment. The Judet technique, involving transpedicular screw fixation, offers a targeted approach to stabilize C2 pedicle fractures while preserving cervical motion.

View Article and Find Full Text PDF

Purpose: The proximal femur is a frequent site of cancer dissemination in the extremities. Patients treated surgically for skeletal metastases have poorer overall health compared to other orthopedic patients, with only one-third expected to survive two years post-surgery. Choosing a treatment that minimizes revision risk and ensures the implant outlives the patient is therefore crucial.

View Article and Find Full Text PDF

Background: Valgus osteotomy is a femoral head-preserving surgery to treat femoral neck non-union in young, active patients. The traditional approach, however, causes medialisation of the femoral shaft during valgus correction, which alters femoral anatomy and complicates conversion to total hip arthroplasty if head osteosynthesis fails. This study aims to outline a novel surgical technique, medial opening wedge valgus intertrochanteric osteotomy (VITO), and evaluate its clinical and radiographic outcomes, focusing on restoring hip biomechanics and improving union rates.

View Article and Find Full Text PDF

Purpose: This study aims to investigate the stress distribution in bone tissue, implant, abutment, screw, and bridge restoration when the mesial implant is placed axially and the distal implant is inserted at varying angles in the posterior maxillary region with free-end partial dentition defects, using three-dimensional finite element analysis.

Materials And Methods: Cone-beam computed-tomography were utilized to create 3D reconstruction models of the maxilla. Stereolithography data of dental implants and accessories were used to design a three-unit full zirconia bridge for the maxillary model.

View Article and Find Full Text PDF

Background And Purpose: Distal ulna fractures often occur in conjunction with distal radius fractures and other associated injuries. Currently, there are no satisfactory internal fixation systems available for addressing unstable distal ulna fractures, and a definitive consensus on the most effective treatment approach is still lacking. The objective of this research was to evaluate the clinical outcomes of using elastic stable intramedullary nails (ESIN) compared to locking compression plates (LCP) for treating unstable distal ulnar fractures in adults.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!