Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1057
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3175
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: To determine the clinical performance of long-term temporary fixed dental prostheses (LTFDPs) manufactured from CAD/CAM temporary resin-based composite.
Materials And Methods: Retrospective data of 46 patients supplied with 73 LTFDPs (partial coverage crowns, crowns, fixed dental prostheses) manufactured from a CAD/CAM resin-based composite luted either temporarily, selfadhsesively, or adhesively were analyzed for failures and complications.
Results: Datasets of 44 patients with 71 LTFDPs (12 partial-coverage crowns, 31 crowns, 28 fixed dental prostheses) were included in the analyses; median observation time was 362.0 days. Failures due to fracture occurred in 14.1% and decementation was observed in 18.1% of all LTFDPs. There was no statistically significant difference in failure rates between partial coverage crowns, crowns, and fixed dental prostheses. The probability of decementations was significantly higher in restorations that had been luted temporarily or selfadhesively than in those that had been luted adhesively.
Conclusions: LTFDPs fabricated from resin-based temporary composite with low filler content feature relevant failure rates, which is independent on the type of restoration. Decementation is a frequently observed complication and dependent on the mode of luting.
Clinical Relevance: LTFDPs fabricated from resin-based composite have similar failure rates as reported for polymethyl methacrylate based LTFPDs. Adhesive luting might help to reduce the probability of decementation.