A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3145
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Determinants of elevation of high sensitivity cardiac troponin T after an atrial septal defect percutaneous closure]. | LitMetric

Objectives: The aim was to determine the relationship between the elevation of ultrasensitive troponin T (hs-cTnT) after percutaneous atrial septal defect (ASD) closure with deficient aortic rim and with standard and specific maneuvers of the intervention.

Method: Baseline hs-cTnT was measured and repeated 6 hours after the procedure. To determine the influence of independent variables with the dependent variable (change in hs-cTnT), a generalized linear mixed model was used.

Results: The total cohort consisted in 106 patients. The median age was 8 years, and 22 patients (21%) were older than 18 years. The hs-TnT before the procedure was 3.7 pg/ml and 6 hours after the intervention was finalized was 72.5 pg/ml. The hs-TnT at 6 hours was similar in patients with sufficient vs. deficient aortic rim. A generalized linear mixed model demonstrated a direct relationship between hs-cTnT change and ASD diameter (β: 2.8; CI: 0.8 to 4.9; p < 0.01) and fluoroscopy time (β: 2.7; CI: 0.6 to 4.7; p < 0.01) and an inverse relationship between hs-cTnT change and patient weight (β: -0.7; CI: -1.1 to -0.3; p < 0.01).

Conclusions: The increase in hs-cTnT after percutaneous ASD treatment was directly related to ASD diameter and the fluoroscopy time and inversely to the patient weight. Aortic rim deficit was not associated with elevation of hs-cTnT.

Download full-text PDF

Source
http://dx.doi.org/10.24875/ACM.24000076DOI Listing

Publication Analysis

Top Keywords

aortic rim
12
atrial septal
8
septal defect
8
hs-ctnt percutaneous
8
deficient aortic
8
generalized linear
8
linear mixed
8
mixed model
8
relationship hs-ctnt
8
hs-ctnt change
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!