Urolithiasis guidelines still rely on the maximum stone diameter to propose treatment strategy, although this measure is known to have many pitfalls. Stone volume (SV) could represent a more accurate measurement, helping to plan the treatment or follow-up. Various methods to measure SV have been proposed. We aimed to compare different methods to estimate SV. Fifteen stones (human and artificial) were assessed. Real SV was measured using the water displacement method. Volume estimation included three diameter-based formulas (Ackerman, 4/3 Pi r and r/2) and two 3D segmentation methods (Horos and Kidney Stone Calculator [KSC]). All measurements were done by a single operator. Spearman correlation test and comparative analyses were conducted between the real and the estimated SV. Compared with real SVs, Ackerman and r/2 formulas estimated volume accurately in 2/15 (13%) of stones each. No accurate measurement was reported using the sphere formula. KSC did estimate volume accurately in 4/15 (27%) stones compared with the reference SV; Horos did it in 7/15 (47%) stones. Both segmentation methods presented strong correlation coefficients ( = 0.9642 and 0.9659, < 0.0001), while formula correlation was moderate ( = 0.7531, < 0.0001). Formulas and segmentation methods for SV estimation resulted in divergent outcomes. Segmentation methods (Horos and KSC) presented higher accuracies in SV estimation, compared with real SV. Formulas were the least accurate.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1089/end.2024.0524 | DOI Listing |
Eur J Cardiothorac Surg
March 2025
Department of Cardiothoracic Surgery, NewYork-Presbyterian Hospital/Weill Cornell Medical Center, New York, NY 525 E 68 St, M-404, New York, NY 10065, USA.
Objectives: Compare oncologic outcomes between single-segment and multi-segment resections in patients with clinical stage IA1 and IA2 non-small cell lung cancer.
Methods: A retrospective review (2011-2022) was conducted using a prospectively maintained database. Patients undergoing anatomical segmentectomy for clinical stage IA ≤ 2 cm non-small cell lung cancers were included.
Gigascience
January 2025
Concordia University, Department of Computer Science and Software Engineering, 1455 Blvd. De Maisonneuve Ouest, Montreal, Quebec H3G 1M8, Canada.
Magnetic resonance imaging (MRI) preprocessing is a critical step for neuroimaging analysis. However, the computational cost of MRI preprocessing pipelines is a major bottleneck for large cohort studies and some clinical applications. While high-performance computing and, more recently, deep learning have been adopted to accelerate the computations, these techniques require costly hardware and are not accessible to all researchers.
View Article and Find Full Text PDFInt J Comput Assist Radiol Surg
March 2025
CAMP, Technical University of Munich, Munich, Germany.
Purpose: The multi-modality imaging system offers optimal fused images for safe and precise interventions in modern clinical practices, such as computed tomography-ultrasound (CT-US) guidance for needle insertion. However, the limited dexterity and mobility of current imaging devices hinder their integration into standardized workflows and the advancement toward fully autonomous intervention systems. In this paper, we present a novel clinical setup where robotic cone beam computed tomography (CBCT) and robotic US are pre-calibrated and dynamically co-registered, enabling new clinical applications.
View Article and Find Full Text PDFEur J Orthop Surg Traumatol
March 2025
Nihon University School of Medicine, Itabashiku, Tokyo, Japan.
Purpose: Several risk factors for adjacent segment disease (ASD) after posterior lumbar interbody fusion (PLIF) have been reported. High pelvic incidence (PI) has been identified as risk factors for L4 anterior slip in cases of lumbar degenerative spondylolisthesis. Correcting the slip with L4-L5 fixation merely restores the lumbar alignment, but the PI itself remains unchanged.
View Article and Find Full Text PDFDoc Ophthalmol
March 2025
Department of Ophthalmology, Mie University School of Medicine, 2-174 Edobashi, Tsu, Mie, 514-8507, Japan.
Purpose: To report our flicker electroretinographic (ERG) findings in a patient who developed uveitis after treatment with immune checkpoint inhibitors (ICIs) for a metastatic malignant melanoma.
Methods: ERGs were used to monitor retinal physiology in a patient with ocular complications following systemic ICI administration. Flicker ERGs were recorded using the RETeval system before and after the ICI treatments.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!