A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1057
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3175
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

CARDIAC ASSESSMENTS AND IMPLANTABLE LOOP RECORDER PLACEMENT IN THREE MALE GELADAS (). | LitMetric

Cardiac disease is a common cause of mortality in many primates housed in zoological settings. At the Bronx Zoo, between 2007 and 2018, there were ten incidences of sudden cardiac death in adult male geladas (), none of which showed premonitory signs. Due to concerns of occult cardiac disease and fatal arrhythmogenic events, complete cardiac examinations were performed in three clinically normal, adult male geladas. Examinations included thoracic radiographs, transthoracic echocardiograms (echo), 12-lead ECG, and continuous ECG monitoring using an Implantable Loop Recorder (Reveal LINQ Medtronic, Minneapolis, MN 55432, USA). Serum lipid profiles, vitamin E concentration, cardiac troponin I isoform (cTnI), and complete blood work were also performed. Wireless downloads from the implantable loop recorders were obtained intermittently for up to 2.5 years after placement. One male had an elevated cTnI level (210 ng/L), reduced ejection fraction (46%), and multiple episodes of supraventricular tachycardia and non-sustained ventricular tachycardia. Due to the abnormalities on ECG and echo, he was treated with metoprolol and lisinopril. Treatment was continued for nearly two years, until the animal had sudden cardiac death secondary to sustained ventricular fibrillation, which was confirmed by postmortem download of the loop recorder data and correlated with histologic evidence of cardiomyopathy. Implantable loop recorders greatly enhance the ability to diagnose and treat arrhythmias in primates and understand the mechanisms behind sudden cardiac deaths. Further studies are needed to establish cTnI, echocardiogram, and electrocardiogram reference ranges for this species, as well as appropriate treatment protocols.

Download full-text PDF

Source
http://dx.doi.org/10.1638/2024-0044DOI Listing

Publication Analysis

Top Keywords

implantable loop
16
loop recorder
12
male geladas
12
sudden cardiac
12
cardiac
8
cardiac disease
8
cardiac death
8
adult male
8
loop recorders
8
loop
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!