AI Article Synopsis

  • Keratoprosthesis offers a potential solution for vision impairment due to corneal diseases, but existing implants face postoperative complications, prompting research into better materials.
  • This study examines two specific copolymers (15% MEMA: 85% HEMA and 15% PhEMA: 85% HEMA) as alternative corneal implant materials by analyzing their ability to support the adhesion of human keratocytes.
  • The results indicate that substrate stiffness and mechanical properties of these copolymers significantly influence keratocyte adhesion and behavior, which could lead to improved outcomes in corneal implant applications.

Article Abstract

Keratoprosthesis is an alternative treatment for visual impairment caused by corneal diseases. However, due to the recognized postoperative complications in available Kpros, there is an exigency to explore potential alternative skirt materials for corneal implants. This study aims to investigate the suitability of poly(2-methoxyethyl methacrylate--2-hydroxyethyl methacrylate) (15% MEMA: 85% HEMA), and poly(2-phenoxyethyl methacrylate--2-hydroxyethyl methacrylate) (15% PhEMA: 85% HEMA) copolymers as a corneal implant material by evaluating their ability to adhere human keratocytes. The effect of chemical and mechanical properties of copolymers on the keratocyte cell adhesion was investigated. These copolymers are thermally stable with a glass transition temperature between 75 and 80 °C, and thermogravimetric analysis showed that the copolymers do not degrade until 190 °C. Sum frequency generation spectroscopy (SFG) and atomic force microscopy (AFM) were employed to evaluate the surface chemical and mechanical properties of the polymer thin films. SFG spectra showed the contributions of methylene (CH) and α-methyl (α-CH) functional groups at the air/polymer interface. Moreover, the signature vibrational modes of methoxy (-OCH) and phenoxy (-OPh) groups were detected at the 15% MEMA: 85% HEMA and 15% PhEMA: 85% HEMA copolymer surfaces that contribute to chemical composition surface analysis. Meanwhile, the analysis of the AFM topographical images showed that the 15% MEMA: 85% HEMA copolymer is relatively rougher with a root-mean-square value of 56 nm but was found to be more elastic than the 15% PhEMA: 85% HEMA copolymer with a Young's modulus value of 0.39 GPa. Fluorescence microscopy images showed visible F-actin filaments on stiffer substrates, demonstrating the ability to regulate cell adhesion and migration behavior based on the nanomechanical characteristics of implants. The results show that substrate stiffness can regulate keratocyte cell adhesion as keratocytes preferred to adhere on a stiffer 15% PhEMA: 85% HEMA copolymer surface than the 15% MEMA: 85% HEMA copolymer surface.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.4c21538DOI Listing

Publication Analysis

Top Keywords

85% hema
32
hema copolymer
20
cell adhesion
16
15% mema
16
mema 85%
16
15% phema
16
phema 85%
16
keratocyte cell
12
thin films
8
methacrylate--2-hydroxyethyl methacrylate
8

Similar Publications

Influence of Surface Chemistry and Nanomechanical Properties of Methacrylate-Based Copolymer Thin Films on Keratocyte Cell Adhesion.

ACS Appl Mater Interfaces

March 2025

Department of Chemistry and Biochemistry, Ohio University, 133 University Terrace, Chemistry Building, Athens, Ohio 45701, United States.

Article Synopsis
  • Keratoprosthesis offers a potential solution for vision impairment due to corneal diseases, but existing implants face postoperative complications, prompting research into better materials.
  • This study examines two specific copolymers (15% MEMA: 85% HEMA and 15% PhEMA: 85% HEMA) as alternative corneal implant materials by analyzing their ability to support the adhesion of human keratocytes.
  • The results indicate that substrate stiffness and mechanical properties of these copolymers significantly influence keratocyte adhesion and behavior, which could lead to improved outcomes in corneal implant applications.
View Article and Find Full Text PDF

This study evaluates the health-related quality of life (HRQoL) among patients with hemophilia A currently undergoing prophylactic treatment at the Hemophilia Center of Northern Greece. Using the Haem-A-QoL questionnaire, we assessed various HRQoL dimensions in a cohort of 29 adult male patients, analyzing the impact of age, disease severity, and treatment regimens. The results revealed that younger patients (18-30 years old) exhibited significantly better overall HRQoL scores (total score of 25.

View Article and Find Full Text PDF

Introduction: Despite its rarity, cutaneous melanoma (CM) represents the deadliest skin cancer with a high mortality rate, an incidence on the rise, and limited therapeutic options at present. Melanin is a polymeric pigment naturally produced within melanocytes and CM cells that gained a noteworthy attention due to its pharmacological properties, and potential for the design of nanoplatforms with biomedical applications. Up to date, the utilization of melanin-like nanoparticles (MEL-NPs) in cancer treatment has been well-documented, although their efficacy in CM therapy remains scarcely investigated.

View Article and Find Full Text PDF

Background: Healthcare-associated infections (HAIs) are one of the most common adverse events in healthcare and represent a major public health problem. The present study was conducted to analyze the incidence, risk factors, and outcomes of HAIs through active surveillance in three hospitals in the city of Bobo Dioulasso, Burkina Faso.

Methods: A prospective, longitudinal, multicenter study was conducted from May 1 to November 30, 2022, in two district hospitals (Do and Dafra) and the Sourô Sanou Teaching Hospital (CHUSS), Burkina Faso.

View Article and Find Full Text PDF

Evaluation of Healthcare Outcomes of Patients Treated with 3D-Printed-Titanium and PEEK Cages During Fusion Procedures in the Lumbar Spine.

Med Devices (Auckl)

January 2025

MedTech Epidemiology and Real-World Data Science, Johnson & Johnson, Raynham, Massachusetts & New Brunswick, New Jersey, USA.

Purpose: The objective of this observational, real-world study was to describe reoperation, revision, index healthcare utilization and hospital costs among patients treated with PEEK (polyetheretherketone) or 3D-printed-titanium cages during lumbar/lumbosacral posterior fusion procedures, either TLIF (transforaminal lumbar interbody fusion) or PLIF (posterior lumbar interbody fusion). Statistical comparisons were not conducted.

Methods: This was a descriptive, retrospective, observational study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!