Advanced Hemodynamic Monitoring: Are We Asking the Right Questions?

Anesthesiology

Department of Anesthesia and Perioperative Care, University of California-San Francisco, San Francisco, California.

Published: April 2025

Download full-text PDF

Source
http://dx.doi.org/10.1097/ALN.0000000000005373DOI Listing

Publication Analysis

Top Keywords

advanced hemodynamic
4
hemodynamic monitoring
4
monitoring questions?
4
advanced
1
monitoring
1
questions?
1

Similar Publications

Purpose: Central hypovolemia is considered to lead to a compensatory increase in cardiac contractility. From a physiological perspective, left ventricular (LV) twisting motion, which plays an important role in maintaining cardiac output, should be enhanced during central hypovolemia, but previous studies have shown inconsistent findings. Using 3D echocardiography, we tested the hypothesis that the LV twisting and untwisting motion would be enhanced during severe central hypovolemia.

View Article and Find Full Text PDF

Digital subtraction angiography (DSA) is the gold standard for assessing cerebrovascular hemodynamics. DSA is predominantly utilized to evaluate the hemodynamic information of various cerebral diseases. However, DSA is relatively invasive and involves radiation exposure and risks of allergic reactions or renal dysfunction related to iodine-based contrast agents.

View Article and Find Full Text PDF

Unlabelled: Four-dimensional flow cardiovascular magnetic resonance (4D Flow cardiac MRI) is an advanced non-invasive imaging technology, and its derived kinetic energy (KE) blood flow parameters have been confirmed as a potential biomarkers for assessing ventricular hemodynamics. This review synthesizes details on the methodology, clinical significance, and current status of studies focused on quantifying KE parameters of the ventricle using 4D Flow cardiac MRI, providing an objective foundation for further exploration of the value of KE in cardiac diseases.

Study Type: retrospective.

View Article and Find Full Text PDF

Objective: This study aims to compare the cognitive workload levels of general surgery residents by measuring prefrontal cortex hemodynamic activity while performing a similar task using robotic-assisted surgery (RAS) and laparoscopic surgery simulators.

Design: The study was conducted with 22 general surgery residents who completed a peg transfer task in simulated laparoscopic and RAS training environments. Participants' performance and neurophysiological data were collected over a 1-month period.

View Article and Find Full Text PDF

Background: The rising growth of patients with end-stage kidney disease (ESKD) associated with chronic liver disease (CLD) and refractory chronic heart failure (CHF) associated with advanced chronic kidney disease (CKD) complicated by ascites presents serious renal replacement therapy (RRT) challenges. Haemodialysis is often poorly tolerated owing to increased hemodynamic instability, bleeding, and encephalopathy risks. Peritoneal dialysis (PD) has emerged as a promising alternative, but its adoption and efficacy are not consistently supported by existing literature, and there lacks guideline consensus.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!