Aims: Whether the intraprocedural anticoagulation regimen and activated clotting time (ACT) in pulsed field ablation (PFA) for atrial fibrillation (AF) are the same as those for radiofrequency catheter ablation (RFCA) is currently unknown.
Methods And Results: Our retrospective study included 51 paroxysmal AF patients who underwent PFA (PFA group) and were matched with paroxysmal AF patients who underwent RFCA. Nearest-neighbor propensity score matching was performed at a 1:1 ratio (no tolerance to anticoagulant regimens and a tolerance of 0.02 on the CHADS-VASc score, left atrial diameter, and left ventricular ejection fraction). Compared with the RFCA group, the PFA group had a significantly shorter procedure time but a longer fluoroscopy time. In both groups, an initial heparin dose of 110 U/kg was given. The 30-min ACT in the PFA group (240 ± 95.5 s) was shorter than that in the RFCA group (294.4 ± 82.3 s, = 0.003). The 60-, 90-, and 120-min ACTs were significantly longer in the PFA group. The percentage of 30 min-ACTs in the therapeutic range in the RFCA group (33.3%) was greater than that in the PFA group (15.7%, = 0.038). The time to achieve the target ACT was longer in the PFA group. There were no differences in the incidence of periprocedural thromboembolism or bleeding events between the two groups.
Conclusions: Compared with RFCA, PFA was associated with longer intraprocedural ACTs, shorter initial ACTs, fewer initial ACTs in the therapeutic range, and longer times to achieve the target ACT.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11891359 | PMC |
http://dx.doi.org/10.3389/fcvm.2025.1501716 | DOI Listing |
Front Cardiovasc Med
February 2025
Department of Cardiology, Institute of Cardiovascular Diseases, First Affiliated Hospital of Dalian Medical University, Dalian, China.
Aims: Whether the intraprocedural anticoagulation regimen and activated clotting time (ACT) in pulsed field ablation (PFA) for atrial fibrillation (AF) are the same as those for radiofrequency catheter ablation (RFCA) is currently unknown.
Methods And Results: Our retrospective study included 51 paroxysmal AF patients who underwent PFA (PFA group) and were matched with paroxysmal AF patients who underwent RFCA. Nearest-neighbor propensity score matching was performed at a 1:1 ratio (no tolerance to anticoagulant regimens and a tolerance of 0.
J Interv Card Electrophysiol
March 2025
Heart Rhythm Management Centre, Universitair-Ziekenhuis Brussel, Brussels, Belgium.
Background: Patients undergoing atrial fibrillation (AF) catheter ablation may require redo procedures involving pulmonary vein (PV) re-isolation and/or ablation of extra-PV sites. Pulsed field ablation (PFA) offers a highly selective energy source for cardiac tissue, with the potential to reduce collateral damage to adjacent structures. This study aimed to evaluate the feasibility and efficacy of redo ablation using a pentaspline PFA system.
View Article and Find Full Text PDFJ Appl Physiol (1985)
February 2025
Department of Neurosciences, Deglutology, Research group Experimental Otorhinolaryngology (ExpORL), University of Leuven (KU Leuven), Leuven, Belgium.
Background: Despite positive clinical evidence for the effects of Pharyngeal Electrical Stimulation (PES) on swallowing performance in disease, it remains unknown which specific swallow characteristics improve. Using High Resolution Manometry Impedance (HRMI) with Pressure Flow Analysis (PFA), we aimed to assess the effects of PES on normal swallow function and to evaluate the impact of pharyngeal length variability on electrode placement.
Methods: As part of a prospective RCT, 20 asymptomatic volunteers were randomly assigned to three days of PES or SHAM treatment.
J Mech Behav Biomed Mater
May 2025
Institute for Biomedical Engineering, Rostock University Medical Center, Germany.
For the development of stent-based intraluminal prostheses to treat chronic venous insufficiency, comprehensive knowledge of morphometric and mechanical parameters of the femoral veins (FV) is crucial for an optimized implant design. These data is essential as input for material models for numerical simulations of venous valves prostheses. However, data on mechanical properties of native/unfixed FV tissue are scarce.
View Article and Find Full Text PDFHealthcare (Basel)
February 2025
Provincial Patient and Family Group, Alberta Health Services, Edmonton, AB T5J 3E4, Canada.
Background: Healthcare setting teams were challenged to understand how and what to measure regarding healthcare quality improvement (HQI), who should be involved, and what approach to apply. We aimed to determine if a generic co-design approach involving patients/families, multi-disciplinary care providers, and other staff was feasible to apply for HQI across diverse care settings. Developmental evaluation embedded in the co-design approach would determine its effectiveness, challenges, and other experiences across care settings and teams.