Unlabelled: Cochlear implant surgery is an auditory prosthesis that helps to restore the hearing in people who have severe to profound sensorineural hearing loss. In view of the variations in individual's cochlear size, appropriate selection of cochlear electrode is important to enable appropriate pitch detection in cochlear implant surgery. In traditional 24 mm electrodes were used in earlier the days. Longer electrode with deeper insertion were always recommended for stimulation of lower frequencies of hearing at apex of cochlear. However, it was avoided to prevent possibility of electrode insertion injury. We are using an indirect measuring method in measuring cochlear duct length by uploading patient's computed topography images of cochlear onto a validated software named "OTOPLAN" prior to cochlear implant surgery. This software can provide information on the morphology of cochlear, which includes width, height, and diameter as well as the cochlear duct length. In results, we recruited 30 patients from age 2-76 years old, who are fitted into the inclusion criteria with total of forty-five cochlear reviewed in 3 years duration. Our patients show an average cochlear duct length of 33.5 mm with a range of 30.1-36.0 mm. Majority of patients were implanted with 28 mm electrode. Patients had an average of 83% of cochlear duct covered with inserted electrode with average 77.8-92.7%. Identification of variation of cochlear anatomy and electrode selection gives an optimal pre-operative planning and appropriate electrode selection in cochlear implant surgery.
Supplementary Information: The online version contains supplementary material available at 10.1007/s12070-024-05259-6.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11890486 | PMC |
http://dx.doi.org/10.1007/s12070-024-05259-6 | DOI Listing |
Indian J Otolaryngol Head Neck Surg
February 2025
Department of Otorhinolaryngology, University of Malaya, Kuala Lumpur, Malaysia.
Unlabelled: Cochlear implant surgery is an auditory prosthesis that helps to restore the hearing in people who have severe to profound sensorineural hearing loss. In view of the variations in individual's cochlear size, appropriate selection of cochlear electrode is important to enable appropriate pitch detection in cochlear implant surgery. In traditional 24 mm electrodes were used in earlier the days.
View Article and Find Full Text PDFOtol Neurotol
February 2025
Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany.
Introduction: Preoperative anatomical assessment is essential to optimize the outcome of individualized cochlear implantation. Algorithms based on cochlear diameters simplify this evaluation. The new version of a surgical planning platform is capable of performing this determination automatically.
View Article and Find Full Text PDFCell Death Dis
February 2025
Otorhinolaryngology Hospital, The First Affiliated Hospital, Sun Yat-sen University, 58 Zhongshan Road II, Guangzhou, Guangdong, 510080, China.
According to the World Health Organization, more than 12% of the world's population suffers from noise-induced hearing loss (NIHL). Oxidative stress-mediated damage to the stria vascularis (SV) is one of the pathogenic mechanisms of NIHL. Recent studies indicate that glycolysis plays a critical role in endothelial cells (ECs)-related diseases.
View Article and Find Full Text PDFAJNR Am J Neuroradiol
February 2025
Department of Diagnostic and Interventional Radiology (B.P., T.A.B., J.-P.G., H.H.), University Hospital Würzburg, Würzburg, Germany
Background And Purpose: Anatomically adapted cochlear implantation and efficient postoperative cochlear implant-fitting strategies benefit from reliable and highly detailed imaging techniques. Since image quality in CT is related to the applied radiation dose, this study aimed to evaluate low-dose cochlear imaging with a photon-counting detector by investigating the accuracy of pre- and postoperative cochlear analysis.
Materials And Methods: Photon-counting CT images of 10 temporal bone specimens were acquired with 3 different radiation dose levels (regular dose: 27.
J Vis Exp
January 2025
King Abdullah Ear Specialist Center (KAESC), College of Medicine, King Saud University Medical City (KSUMC), King Saud University.
This study aimed to determine whether fusing pre- and post-operative computed tomography (CT) images could help in assessing electrode placement and center frequency (CF) in cochlear implant (CI) recipients. A secondary objective was to compare automatic fusion with manual methods for measuring cochlear parameters. The study included twenty ears with CIs that underwent both pre- and post-operative CT scans.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!