Small-sized right ventricle to pulmonary artery conduits are hindered by calcification, degeneration, or infective endocarditis and face limited availability. Valved conduits of expanded polytetrafluoroethylene leaflets offer a promising path toward enhanced longevity and performance. This in-vitro study introduces innovative expanded polytetrafluoroethylene valve designs for small-sized conduits.Three bicuspid and three tricuspid expanded polytetrafluoroethylene leaflets designed for size 12 mm were tested using an in-vitro pediatric right-heart mock-up loop and compared with our baseline leaflet design. Polyvinylchloride was used to create a transparent tube for visual access. Regurgitation rates, pressure gradients, effective orifice area under 0.5-3 L/min cardiac outputs, and 100-150beats/min heart rates are measured. Mechanical differences between expanded polytetrafluoroethylene and polyvinylchloride are investigated through biaxial strain tests. In newborn hemodynamic conditions, 0.5-1 L/min cardiac output, bileaflet valves demonstrated regurgitation rates below 20%, and two tricuspid models maintained regurgitation rates below 15% with gradients below 25 mmHg. In infant conditions, 1-3 L/min output, the regurgitation rates of trileaflet models were below 20%, with gradients consistently below 35 mmHg. The fully coapting bileaflet model showed a regurgitation rate of less than 15% and a gradient below 30 mmHg across newborn and infant conditions. A circumferential difference of less than 0.12 mm was detected between expanded polytetrafluoroethylene and polyvinylchloride. Both the fully coapting bileaflet and redundant trileaflet configurations can be integrated in the small conduits. Polyvinylchloride can be an alternative to expanded polytetrafluoroethylene tube graft in in-vitro studies, allowing visual access to assess leaflet kinematics.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbiomech.2025.112613DOI Listing

Publication Analysis

Top Keywords

expanded polytetrafluoroethylene
24
regurgitation rates
16
polytetrafluoroethylene leaflets
8
visual access
8
polytetrafluoroethylene polyvinylchloride
8
infant conditions
8
fully coapting
8
coapting bileaflet
8
expanded
6
polytetrafluoroethylene
6

Similar Publications

Small-sized right ventricle to pulmonary artery conduits are hindered by calcification, degeneration, or infective endocarditis and face limited availability. Valved conduits of expanded polytetrafluoroethylene leaflets offer a promising path toward enhanced longevity and performance. This in-vitro study introduces innovative expanded polytetrafluoroethylene valve designs for small-sized conduits.

View Article and Find Full Text PDF

Background: There is no consensus on the preferred conduit for right ventricular outflow tract (RVOT) reconstruction for congenital cardiac disease.

Case Summary: We present a case of a 21-year-old woman with history of tetralogy of Fallot presenting with recurrent graft thrombosis and pulmonary emboli in the setting of RVOT reconstruction with a 20-mm expanded polytetrafluoroethylene (ePTFE) valved conduit (GORE PV1, W.L.

View Article and Find Full Text PDF

Beating heart superior caval vein replacement for giant venous aneurysm: a case report.

Eur Heart J Case Rep

March 2025

Department of Cardiac and Thoracic Aortic Surgery, Medical University of Vienna, Spitalgasse 23, 1090 Vienna, Austria.

Background: Superior vena cava (SVC) aneurysms are rare vascular anomalies, with <80 cases reported worldwide. Large aneurysms carry a risk of rupture and thrombosis, eventually necessitating surgical intervention.

Case Summary: We present the case of a 68-year-old male with a progressively enlarging SVC aneurysm and a history of paroxysmal atrial fibrillation.

View Article and Find Full Text PDF

Living donor liver transplantation (LDLT) is a useful therapeutic option for end-stage liver disease due to the shortage of deceased donor liver grafts, particularly in Asia and Türkiye. Right liver LDLT is frequently performed in adults and some cases require anterior section venous drainage. Synthetic grafts, particularly expanded polytetrafluoroethylene (e-PTFE), are often preferred for venoplasties.

View Article and Find Full Text PDF

Nucleophilic cleavage of C-F bonds by Brønsted base for rapid synthesis of fluorophosphate materials.

Natl Sci Rev

March 2025

College of Materials Science and Engineering, Hunan Joint International Laboratory of Advanced Materials and Technology for Clean Energy, Hunan Province Key Laboratory for Advanced Carbon Materials and Applied Technology, Hunan University, Changsha 410082, China.

Fluorochemicals are a rapidly expanding class of materials used in a variety of fields including pharmaceuticals, metallurgy, agrochemicals, refrigerants, and in particular, alkali metal ion batteries. However, achieving one-step synthesis of pure fluorophosphate compounds in a well-controlled manner remains a formidable challenge due to the volatilization of fluorine during the heat treatment process. One feasible method is to cleave the C-F bond in polytetrafluoroethylene (PTFE) during synthesis to create a fluorine-rich atmosphere and strongly reducing environment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!