Biological effects of high-LET irradiation on the circulatory system.

Int J Radiat Biol

Biology and Environmental Chemistry Division, Sustainable System Research Laboratory, Central Research Institute of Electric Power Industry (CRIEPI), Chiba, Japan.

Published: March 2025

Purpose: High-linear energy transfer (LET) radiation is generally thought to be more biologically effective in various tissues than low-LET radiation, but whether this also applies to the circulatory system remains unclear. We therefore reviewed biological studies about the effects of high-LET radiation on the circulatory system.

Conclusions: We identified 76 relevant papers (24 in vitro, 2 ex vivo, 51 in vivo, one overlapping). In vitro studies used human, bovine, porcine or chick vascular endothelial cells or cardiomyocytes, while ex vivo studies used porcine hearts. In vivo studies used mice, rats, rabbits, dogs or pigs. The types of high-LET radiation used were neutrons, α particles, heavy ions and negative pions. Most studies used a single dose, although some investigated fractionation effects. Twenty-one studies estimated the relative biological effectiveness (RBE) that ranged from 0.1 to 130, depending on radiation quality and endpoint. A meta-analysis of 6 in vitro and 8 in vivo studies (selected based on the feasibility of estimating the RBE and its uncertainty) suggested an RBE of 6.69 (95% confidence intervals (CI): 2.51, 10.88) for in vitro studies and 1.14 (95% CI: 0.91, 1.37) for in vivo studies. The meta-analysis of these 14 studies yielded an RBE of 2.88 (95% CI: 1.52, 4.25). This suggests that high-LET radiation is only slightly more effective than low-LET radiation, although substantial inter-study heterogeneity complicates interpretation. Therapeutic effects have also been reported in disease models. Further research is needed to better understand the effects on the cardiovascular system and to improve radiation protection.

Download full-text PDF

Source
http://dx.doi.org/10.1080/09553002.2025.2470947DOI Listing

Publication Analysis

Top Keywords

vivo studies
16
high-let radiation
12
studies
10
effects high-let
8
circulatory system
8
radiation
8
low-let radiation
8
vitro vivo
8
vitro studies
8
vivo
6

Similar Publications

More than a decade since its introduction, the polymeric excipient Soluplus continues to receive considerable attention for its application in the development of amorphous solid dispersions (ASDs) and its utility as a solubilizer for drugs exhibiting solubility limited absorption. While it is well-recognized that Soluplus forms micelles, the impact of its lower critical solution temperature of approximately 40 °C remains an underexplored aspect. This study investigated the phase behavior of Soluplus in fasted-state simulated intestinal fluid (FaSSIF-V1).

View Article and Find Full Text PDF

Purpose: This study aims to describe an innovative suprachoroidal space injection technique using a combination of 30 G and 22 G needles attached to a 1 ml injector. The efficacy and applicability of this technique in suprachoroidal injections are evaluated.

Methods: In this study, we conducted both and injection experiments using isolated porcine eyes and live SD rats, respectively.

View Article and Find Full Text PDF

Lyophilized monkeypox mRNA lipid nanoparticle vaccines with long-term stability and robust immune responses in mice.

Hum Vaccin Immunother

December 2025

Department of Research & Development, Yither Biotech Co Ltd, Shanghai, China.

The World Health Organization (WHO) has recently declared another global health emergency due to the rapidly spreading monkeypox (Mpox) outbreak in numerous African countries. To address the unmet need to contain the outbreak using the existing vaccines, this study developed a lyophilization process for an effective, scalable and affordable Mpox mRNA-LNP vaccine candidate to address the global health crisis. A comprehensive evaluation and optimization of the vaccine formulation (the type/concentration of cryoprotectants, the type/concentration of buffer system, as well as the mRNA concentration and reconstitution solvent) and the freeze-drying process parameters (freezing method, temperature, cooling rate and primary/secondary drying conditions) were conducted.

View Article and Find Full Text PDF

Orthotopic tumor model has become an essential tool for studying drug biodistribution and tumor progression over time owing to the rapid development of in vivo imaging and immunological science. Dynamic diffuse fluorescence tomography (DFT) is a promising imaging modality that can map the three-dimensional distribution of a fluorophore within the object and capture the metabolic parameters of fluorophores in vivo. It has been widely applied in tumor detection, drug development, and efficacy evaluation.

View Article and Find Full Text PDF

Electromyography (EMG) is a widely used diagnostic technique for evaluating the electrical activity of muscles and their controlling nerves. However, conventional surface electrodes with planar structures often suffer from low spatial resolution and suboptimal signal quality. Here, 3D-shaped, substrate-free, soft, and biocompatible liquid metal electrodes (LMe) are presented as a wearable interface for neuromuscular signal recording.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!