Background: The design of absorbent continence products is important to family caregivers, because it can simplify pad changes, save time and improve lower back posture. However, the ergonomic design of many products has not received sufficient attention.
Aims: The study aimed to assess the time required for handling three types of absorbent continence products and evaluate physical stress on the hand-arm and back-head areas of the participants in both the lying and standing position from an ergonomic perspective.
Methods: Twenty-one non-professionals without prior nursing experience in Germany participated in the study. Objective data, including the time required to apply, change and remove the products three times, the duration of harmful postures, and the subjective evaluation of the products according to ergonomic criteria were investigated.
Findings: There were significant differences between two application positions (lying down versus standing) for all products. Handling the products with the patient in a standing position was faster, requiring less stressful postures and fewer hand grips. Objective data showed that MoliCare premium Elastic was the quickest product to handle and had the shortest duration of unfavourable postures. The MoliFlex (Belted) ranked second in terms of harmful postures, whereas the MoliCare premium Slip performed slightly better than the Belted product in the duration of change in the lying down position.
Conclusion: In the design of absorbent continence products, it is important to consider that comfort and quality are important not only for patients but also for family caregivers. Choosing the correct continence product can minimise the time and physical effort required for product handling.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.12968/bjon.2025.0012 | DOI Listing |
Br J Nurs
March 2025
Global Senior Manager Product Marketing, Paul Hartmann AG, D-89522 Heidenheim, Germany.
Background: The design of absorbent continence products is important to family caregivers, because it can simplify pad changes, save time and improve lower back posture. However, the ergonomic design of many products has not received sufficient attention.
Aims: The study aimed to assess the time required for handling three types of absorbent continence products and evaluate physical stress on the hand-arm and back-head areas of the participants in both the lying and standing position from an ergonomic perspective.
Br J Nurs
December 2024
Director Global Product Marketing, Paul hartmann AG, D-89522 Heidenheim, Germany.
Background: High-quality absorbent products with effective performance characteristics help maintain user dignity and normalise incontinence.
Aim: The study evaluated the most important performance characteristics of newly developed MoliCare Premium Pants.
Methods: Fifty-two adults with incontinence in Germany were surveyed for their views and levels of satisfaction with various performance features of the tested absorbent incontinence product via a computer-assisted personal interview.
J Wound Ostomy Continence Nurs
November 2024
Caroline Borzdynski, BN(Hons), RN, PhD candidate, La Trobe University, Bundoora, Victoria, Australia.
Exp Dermatol
November 2024
Department of Gerontological Nursing/Wound Care Management, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.
Incontinence-associated dermatitis (IAD) is one of the most serious complications in older people with incontinence. Controlling urine property in absorbent pads could be effective for preventing IAD caused by bacterial urine. However, no animal model has been established to evaluate their effectiveness.
View Article and Find Full Text PDFObjective: Over the last two decades one of the main surgical treatment for stress urinary incontinence (SUI) and pelvic organ prolapse (POP) surgery was the insertion of non-absorbable mesh to restore continence and prolapse respectively. Over time complications arose including mesh-associated pain syndrome (MAPS), mesh exposure, mesh, erosion, chronic bladder/vaginal infections, and dyspareunia. Consequently, women chose surgical mesh removal to counter these problems.