Sealing and Chromatographic Performance of Microgroove Columns.

Anal Chem

Department of Chemical Engineering CHIS, Vrije Universiteit Brussel, Brussels 1050, Belgium.

Published: March 2025

In a recent paper, we introduced the concept of structured microgroove columns as a potential solution to obtain perfectly ordered particle beds for nano- and micro-LC. In this concept, spherical particles are either individually positioned (single layer column) or stacked (multilayer column) in a series of interconnected micromachined pockets. After introducing a suitable method to fill the columns efficiently in a one-particle-per-pocket mode, the present contribution addresses the issue of sealing the filled columns and reports on the first flow tests conducted in a microgroove column device. For this purpose, an adapted set of micromachined columns was filled with 10 μm calibrated silica particles and subsequently anodically bonded to a borofloat top plate. The potential chromatographic performance of this first prototype is determined by injecting a band of fluorescent dye into the unretentive column. Reduced plate heights were higher ( = 2 instead of = 1) than theoretically expected, while pressure drop and flow resistance were much closer to the expected value (ϕ = 120 versus 130 expected). It is assumed the plate height deviations from theory are due to the fact that the pockets were somewhat oversized (some 75%), creating unnecessary large dead spaces.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.5c00309DOI Listing

Publication Analysis

Top Keywords

chromatographic performance
8
microgroove columns
8
columns
5
sealing chromatographic
4
performance microgroove
4
columns paper
4
paper introduced
4
introduced concept
4
concept structured
4
structured microgroove
4

Similar Publications

Background: Intestinal microbial metabolites, such as trimethylamine-N-oxide (TMAO) and indoxyl sulfate (IS), have been suggested as markers for the progression of aortic stenosis (AS). However, the impact of transcatheter aortic valve implantation (TAVI) on these intestinal bacterial metabolites has not been evaluated in a multicenter clinical study. The aim of this study was to determine the effect of TAVI on plasma levels of intestinal bacterial metabolites and to assess the predictive value of these metabolites for major adverse cardiovascular events (MACE) following TAVI.

View Article and Find Full Text PDF

In a recent paper, we introduced the concept of structured microgroove columns as a potential solution to obtain perfectly ordered particle beds for nano- and micro-LC. In this concept, spherical particles are either individually positioned (single layer column) or stacked (multilayer column) in a series of interconnected micromachined pockets. After introducing a suitable method to fill the columns efficiently in a one-particle-per-pocket mode, the present contribution addresses the issue of sealing the filled columns and reports on the first flow tests conducted in a microgroove column device.

View Article and Find Full Text PDF

A μSPEed microextraction combined with ultra-performance liquid chromatography (UHPLC) with UV detection was developed for analysing six veterinary antibiotics (tetracycline, chlortetracycline, oxytetracycline, doxycycline, sulfamethoxazole, and trimethoprim) in environmental samples. To optimise extraction, 12 sorbent cartridges, sample loading cycles, volumes, and pH were assayed. The PS/DVB-RP cartridge, three 250 μL sample loading cycles, and two 50-µL elutions with acidified methanol yielded maximum efficiency.

View Article and Find Full Text PDF

Mass production of cation-exchange cryogels and their chromatographic adsorption performance for bioseparation.

J Chromatogr A

February 2025

State Key Laboratory Breeding Base of Green Chemistry Synthesis Technology, College of Chemical Engineering, Zhejiang University of Technology, Chaowang Road 18, Hangzhou 310032, China. Electronic address:

The preparation of cryogels with enhanced protein adsorption capabilities holds significant promise in bioseparation. The challenge of industrializing cryogels lies in achieving efficient large-scale production while maintaining controllable performance characteristics. In this work, 200 of poly (hydroxyethyl methacrylate) (pHEMA) monolithic cryogels were mass-produced per batch by cryo-polymerization.

View Article and Find Full Text PDF

Measurement of antibiotic accumulation in bacteria is essential for full understanding of the mechanisms of antimicrobial resistance but requires a highly sensitive analytical assay. A suitable ultra performance reverse phase liquid chromatographic tandem mass spectrometry (UPLC-MS/MS) method was developed in the electrospray negative ionisation mode for quantifying tobramycin in Pseudomonas aeruginosa cell extracts. P.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!