Purpose Of Review: This review will focus on the current usage and the potential future applications of new imaging techniques on the horizon to study overactive and neurogenic bladder.

Recent Findings: Bladder Near-Infrared Spectroscopy (NIRS) has been used to non-invasively identify bladder outlet obstruction, detrusor overactivity, and other forms of voiding dysfunction, but motion artifact has been a limiting factor preventing widespread adaptation. However, newer NIRS units employ accelerometers which enable isolation and splicing of motion and on-going studies show renewed promise for bladder NIRS. Ultrasound has been successfully used to evaluate bladder outlet obstruction and other forms of LUT. Techniques including m-mode evaluation of micromotion, as well as the assessment of bladder wall thickness, bladder weight, shape/circularity, vibrometry, and elastography have been explored. Dynamic bladder functional magnetic resonance imaging (fMRI) is the newest bladder imaging technology on the horizon and provides a novel method to assess bladder function alongside real-time high-resolution 3D anatomic images.

Summary: Bladder imaging techniques including NIRS, ultrasound, and functional fMRI have been developed and are now being used as noninvasive techniques that could potentially supplement, or even replace, traditional Urodynamics.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11882629PMC
http://dx.doi.org/10.1007/s11884-025-00775-9DOI Listing

Publication Analysis

Top Keywords

imaging techniques
12
bladder
11
techniques horizon
8
horizon study
8
study overactive
8
overactive neurogenic
8
bladder outlet
8
outlet obstruction
8
nirs ultrasound
8
techniques including
8

Similar Publications

Multidrug resistance (MDR) infectious wounds are a major concern due to drug resistance, leading to increased patient morbidity. Lichenysin (LCN), a lipopeptide and biosurfactant obtained from certain strains of , has demonstrated an excellent antimicrobial property. The present study focuses on the fabrication and comprehensive evaluation of LCN-incorporated poly(vinyl alcohol) (PVA)/polycaprolactone (PCL)-based nanofiber scaffolds using an electrospinning technique as a potential wound healing biomaterial for the treatment of MDR infectious wounds in diabetic rats.

View Article and Find Full Text PDF

The IL-6 axis in vascular inflammation: effects of IL-6 receptor blockade on vascular lesions from patients with giant-cell arteritis.

Ann Rheum Dis

March 2025

Vasculitis Research Unit, Department of Autoimmune Diseases, Hospital Clínic (member of European Reference Network [ERN]-for rare diseases RITA), University of Barcelona, Centre de Recerca biomèdica (CRB)-CELLEX, Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Barcelona, Spain. Electronic address:

Objectives: Blocking interleukin (IL)-6-receptor with tocilizumab has been a major advance in the treatment of giant-cell arteritis (GCA), supporting a crucial role of IL-6 receptor signalling. However, nearly half of the patients are not able to maintain glucocorticoid- free remission with tocilizumab. The impact of tocilizumab on vascular lesions of GCA is largely unknown since conflicting results have been obtained by imaging.

View Article and Find Full Text PDF

Comparative Assessment of Real-Time and Offline Short-Lag Spatial Coherence Imaging of Ultrasound Breast Masses.

Ultrasound Med Biol

March 2025

Department of Computer Science, Johns Hopkins University, Baltimore, MD, USA; Department of Electrical & Computer Engineering, Johns Hopkins University, Baltimore, MD, USA; Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA. Electronic address:

Objective: To perform the first known investigation of differences between real-time and offline B-mode and short-lag spatial coherence (SLSC) images when evaluating fluid or solid content in 60 hypoechoic breast masses.

Methods: Real-time and retrospective (i.e.

View Article and Find Full Text PDF

A Revised Optical Coherence Tomography-Derived Calcium Score to Predict Stent Underexpansion in Severely Calcified Lesions.

JACC Cardiovasc Interv

March 2025

Clinical Trials Center, Cardiovascular Research Foundation, New York, New York, USA; Division of Cardiology, Department of Medicine, Columbia University Medical Center/NewYork-Presbyterian Hospital, New York, New York, USA.

Background: Severe calcification is the morphology most strongly associated with stent underexpansion.

Objectives: The aim of this study was to revise an optical coherence tomography (OCT)-derived calcium score to predict stent underexpansion in severely calcified lesions (angle >270°) using a point-based system.

Methods: A retrospective observational study was conducted in which 250 de novo lesions undergoing OCT-guided stenting, with angiographically visible calcium and optical coherence tomographic maximum superficial calcium angle >270°, not subjected to atherectomy or specialty balloon treatment before stent implantation, were randomly divided into derivation (n = 167) and validation (n = 83) cohorts.

View Article and Find Full Text PDF

A global treatment algorithm was developed for the endovascular revascularization of femoropopliteal lesions and chronic total occlusions, aiming toward a more standardized approach to endovascular treatment in patients with peripheral artery disease. The following steps are proposed. 1) Evaluation of lesion morphology based on preprocedural imaging by Duplex sonography and intravenous ultrasound for selection of lesion preparation tools.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!