Purpose: Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
Materials And Methods: A three-unit fixed partial denture was designed and printed using two different printers. The evaluation was taken regarding cleaning method with ethanol (ETH) or isopropanol (IPA), and combining ultrasonic (US) technique for the following groups: group 1, ETH; group 2, ETH+US; group 3, IPA; group 4, IPA+US; and group 5, US. The 3D evaluation was conducted by calculating the mean distance between two specific points and analyzing various angular deviations, utilizing the geometry-embedded library. In addition, visual analysis was performed by creating sectional planes in different points of view. Normality test and independent t-test were performed to compare results between the two printers used in this study. In addition, one-way ANOVA was performed to compare cleaning method groups.
Results: Mean distance results showed statistical differences between printers for groups IPA, US, and IPA+US, whereas no significant differences were found among cleaning methods. Angular measurements were taken at the bucco-lingual, proximal, and occlusal planes to assess deviations in the internal surfaces. Overall results showed a tendency of shrinkage of the printed three-unit fixed partial denture.
Conclusion: Ultrasonic treatment may impact the washing efficiency when used with other cleaning solutions regarding angular and longitudinal deformation. Adequate selection of post-processing methods is crucial to decrease morphological deformities in 3D printed materials.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11886403 | PMC |
http://dx.doi.org/10.4047/jap.2025.17.1.11 | DOI Listing |
J Adv Prosthodont
February 2025
Department of Prosthodontics and Oral Science Research Center, College of Dentistry, Yonsei University, Seoul, Republic of Korea.
Purpose: Three-dimensional (3D) printing must go through a post-processing procedure. This study aimed to evaluate the effects of different cleaning methods on 3D printed three-unit fixed partial dentures using 3D analysis.
Materials And Methods: A three-unit fixed partial denture was designed and printed using two different printers.
Clin Oral Investig
February 2025
Department of Prosthodontics, Faculty of Dentistry, Istanbul Okan University, Istanbul, Turkey.
Objectives: The aim of this study was to investigate the marginal, internal, and occlusal discrepancies of three-unit posterior cobalt-chromium (Co-Cr) fixed dental prostheses (FDPs) produced using five different fabrication techniques.
Materials And Methods: Segmental maxillary models were prepared from polyamide material using a laser sintering method. The maxillary first premolar and first molar teeth were prepared to receive posterior FDPs.
J Dent
February 2025
Department of Prosthodontics and Biomaterials, Centre of Implantology, Medical Faculty, RWTH Aachen University, Pauwelsstraße 30, 52074, Aachen, Germany.
Objective: In recent decades, CAD/CAM-fabricated lithium disilicate restorations have become popular and have been approved for fixed dental protheses (FDPs) up to the second premolar since 2013. This multicenter follow-up study collected long-term clinical data on three-unit anterior and premolar FDPs made of lithium disilicate to evaluate the material's suitability over >10 years.
Methods: Thirty-two patients received a total of 32 three-unit anterior or premolar monolithic lithium disilicate FDPs.
Clin Oral Implants Res
January 2025
Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
Objectives: The purpose of the present prospective case series was to investigate the clinical and radiological outcome of one-piece zirconia implants fabricated from 3Y-TZP with a moderately roughened endosseous surface (Sa = 1.24 μm) to support three-unit fixed dental prostheses (FDP) after five years in function.
Materials And Methods: Twenty-seven patients received a total of 54 implants in a one-stage surgery with immediate provisionalization.
J Clin Med
January 2025
Department of Reconstructive Dentistry, UZB University Center for Dental Medicine Basel, University of Basel, 4058 Basel, Switzerland.
The technical development of implant-supported fixed dental prostheses (iFDP) initially concentrated on the computer-aided manufacturing of prosthetic restorations (CAM). Advances in information technologies have shifted the focus for optimizing digital workflows to AI-based processes for design (CAD). This pre-clinical pilot trial investigated the feasibility of the automatic design of three-unit iFDPs using CAD software (Dental Manger 2021, 3Shape; DentalCAD 3.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!