Equilibrium phase images of the liver using a contrast-enhancement boost instead of the portal vein phase.

World J Radiol

Department of Radiology, Faculty of Medicine, Oita University, Yufu 879-5593, Oita, Japan.

Published: February 2025

Background: Three-phase dynamic computed tomography imaging is particularly useful in the liver region. However, dynamic imaging with contrast media has the disadvantage of increased radiation exposure due to multiple imaging sessions. We hypothesized that the contrast enhancement boost (CE-boost) technique could be used to enhance the contrast in equilibrium phase (EP) images and produce enhancement similar to that of portal vein phase (PVP) images, and if this is possible, EP imaging could play the same role as PVP imaging. We also speculated that this might allow the conversion of three-phase dynamic imaging to biphasic dynamic imaging, reducing patients' radiation exposure.

Aim: To determine if the CE-boost of EP, CE-boost (EP) is useful compared to a conventional image.

Methods: We retrospectively analyzed the cases of 52 patients who were diagnosed with liver cancer between January 2016 and October 2022 at our institution. From these computed tomography images, CE-boost images were generated from the EP and plane images. We compared the PVP, EP, and CE-boost (EP) for blood vessels and hepatic parenchyma based on the contrast-to-noise ratio (CNR), signal-to-noise ratio, and figure-of-merit (FOM). Visual assessments were also performed for vessel visualization, lesion conspicuity, and image noise.

Results: The CE-boost (EP) images showed significant superiority compared to the PVP images in the CNR, signal-to-noise ratio, and FOM except regarding the hepatic parenchyma. No significant differences were detected in CNR or FOM comparisons within the hepatic parenchyma ( = 0.62, 0.67). The comparison of the EP and CE-boost (EP) images consistently favored CE-boost (EP). Regarding the visual assessment, the CE-boost (EP) images were significantly superior to the PVP images in lesion conspicuity, and the PVP in image noise. The CE-boost (EP) images were significantly better than the EP images in the vessel visualization of segmental branches of the portal vein and lesion conspicuity, and the EP in image noise.

Conclusion: The image quality of CE-boost (EP) images was comparable or superior to that of conventional PVP and EP. CE-boost (EP) images might provide information comparable to the conventional PVP.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11885925PMC
http://dx.doi.org/10.4329/wjr.v17.i2.102462DOI Listing

Publication Analysis

Top Keywords

ce-boost images
28
images
15
portal vein
12
dynamic imaging
12
ce-boost
12
pvp images
12
hepatic parenchyma
12
lesion conspicuity
12
equilibrium phase
8
phase images
8

Similar Publications

Background: Three-phase dynamic computed tomography imaging is particularly useful in the liver region. However, dynamic imaging with contrast media has the disadvantage of increased radiation exposure due to multiple imaging sessions. We hypothesized that the contrast enhancement boost (CE-boost) technique could be used to enhance the contrast in equilibrium phase (EP) images and produce enhancement similar to that of portal vein phase (PVP) images, and if this is possible, EP imaging could play the same role as PVP imaging.

View Article and Find Full Text PDF
Article Synopsis
  • This study investigates the effectiveness of two advanced imaging techniques, AiCE and AIDR 3D, combined with or without the black blood CT (BBCT) approach, for detecting vascular invasion in patients with nonmetastatic pancreatic ductal adenocarcinoma (PDAC).
  • A total of 35 patients underwent contrast-enhanced abdominal CT scans, with images analyzed for quality and diagnostic performance by two observers, using metrics like Cohen's kappa and area under the curve (AUC) for evaluation.
  • The findings indicate that the combination of AiCE and BBCT significantly improves image quality and diagnostic accuracy for detecting vascular invasion, demonstrating high sensitivity and specificity, which could influence treatment decisions for patients with PDAC.
View Article and Find Full Text PDF

Utilization of double contrast-enhancement boost for lower-extremity CT angiography.

J Med Imaging (Bellingham)

November 2024

Inje University Ilsan Paik Hospital, Inje University College of Medicine, Department of Radiology, Goyang, Republic of Korea.

Article Synopsis
  • This study aimed to compare the effectiveness of a double contrast enhancement (CE)-boost technique versus traditional methods for improving vascular imaging in lower-extremity CT angiography.
  • A total of 45 patients participated, and the double CE-boost technique was found to significantly reduce image noise and enhance CT attenuation values, resulting in clearer images.
  • The results showed that double CE-boost images had superior quality, higher signal/noise ratios, and better subjective ratings compared to both conventional and single CE-boost images.
View Article and Find Full Text PDF

Objective: This study aimed to evaluate the image quality and visualization of hepatocellular carcinoma (HCC) on arterial phase computed tomography (CT) using the contrast enhancement (CE)-boost technique.

Methods: This retrospective study included 527 consecutive patients who underwent dynamic liver CT between June 2021 and February 2022. Quantitative and qualitative image analyses were performed on 486 patients after excluding 41 patients.

View Article and Find Full Text PDF
Article Synopsis
  • - The study aimed to assess how the contrast-enhancement-boost (CE-boost) technique affects image quality in obese patients during computed tomography pulmonary angiography (CTPA) compared to two other methods: hybrid iterative reconstruction (HIR) and model-based iterative reconstruction (MBIR).
  • - Conducted on 100 patients, the results indicated that CE-boost significantly improved visibility and CT values over HIR and MBIR in both obese and non-obese patients, with MBIR showing the least image noise.
  • - Ultimately, CE-boost outperformed HIR regarding diagnostic confidence and vascular contrast, suggesting it is particularly effective for enhancing pulmonary artery imaging in obese individuals.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!