Liquid handling robots have been developed to automate various steps of the bottom-up proteomics workflow, however, protocols for the generation of isobarically labeled peptides remain limited. Existing methods often require costly specialty devices and are constrained by fixed workflows. To address this, we developed a cost-effective, flexible, automated sample preparation protocol for TMT-labeled peptides using the Biomek i5 liquid handler. Our approach leverages Single-Pot Solid-Phase-Enhanced Sample Preparation (SP3) with paramagnetic beads to streamline protein cleanup and digestion. The protocol also allows for adjustment of trypsin concentration and peptide-to-TMT ratio to increase throughput and reduce costs, respectively. We compared our automated and manual 18-plex TMT-Pro labeling workflows by monitoring select protein markers of the Unfolded Protein Response (UPR) in pharmacologically activatable, engineered cell lines. Overall, the automated protocol demonstrated equivalent performance in peptide and protein identifications, digestion and labeling efficiency, and an enhancement in the dynamic range of TMT quantifications. Compared to the manual method, the Biomek protocol significantly reduces hands-on time and minimizes sample handling errors. The 96-well format additionally allows for the number of TMT reactions to be scaled up quickly without a significant increase in user interaction. Our optimized automated workflow enhances throughput, reproducibility, and cost-effectiveness, making it a valuable tool for high-throughput proteomics studies.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11888279 | PMC |
http://dx.doi.org/10.1101/2025.02.23.639731 | DOI Listing |
Langmuir
March 2025
School of Civil and Hydraulic Engineering, Chongqing University of Science and Technology, Chongqing 401331, China.
Inspired by the "Salvinia effect", a novel method for fabricating a magneto-responsive superhydrophobic surface coated with a cluster-distributed cilia array (CC-MRSS) was reported. This surface features a magnetically self-assembled nonuniform microcilia array and demonstrates exceptional microdroplet hydrophobicity, magnetic-responsive wettability, and corrosion resistance. The fabrication process involved mixing polydimethylsiloxane (PDMS) and carbonyl iron powders (CIPs), followed by dividing the mixture into two parts.
View Article and Find Full Text PDFBest Pract Res Clin Haematol
December 2024
Mellen Center, Neurological Institute, Cleveland Clinic Foundation, United States.
Mesenchymal stem/stromal cells (MSC) have been transplanted for therapeutic purposes with inconsistent results. MSC preparations are heterogeneous, and this person-to-person heterogeneity may account for the variable clinical outcomes. Additionally, the mechanisms of therapeutic action for MSC are unclear which confounds attempts to understand and identify factors that may account for variable clinical results.
View Article and Find Full Text PDFAnal Chim Acta
May 2025
School of Chemistry and Chemical Engineering, Jiangsu University, Zhenjiang, Jiangsu, 212013, PR China; Key Laboratory of Modern Agricultural Equipment and Technology (Ministry of Education), Jiangsu University, Zhenjiang, Jiangsu, 212013 PR China. Electronic address:
Background: Hypochlorous acid (HClO) is a crucial disinfectant in the food industry. It can be used to soak perishable foods like vegetables, fruits, eggs, fish, and raw meat before processing and storage, eliminating microorganisms, bacteria, fungi, and pathogens to ensure food safety. HClO also helps preserve vegetables and fruits by reducing ethylene production, delaying rotting, decreasing cell membrane permeability, inhibiting polyphenol oxidase activity, and postponing discoloration.
View Article and Find Full Text PDFAnal Chim Acta
May 2025
School of Pharmacy, Shenyang Pharmaceutical University, Shenyang, Liaoning, 110016, China. Electronic address:
Background: Herbal medicines and their preparations play a significant role in healthcare systems, yet concerns remain about their quality consistency. Chemical fingerprinting and multi-component quantitative analysis are the commonly used analytical methods and are widely applied in the quality analysis of herbal medicines. The study uses Gegen Qinlian tablets (GQTs) as a case to propose a comprehensive quality consistency evaluation system.
View Article and Find Full Text PDFAnal Chim Acta
May 2025
Department of Chemical Engineering and Analytical Chemistry, University of Barcelona, Av. Diagonal 645, Barcelona, E-08028, Spain.
Background: Ambient Mass Spectrometry (AMS) encompasses a group of techniques that have emerged as powerful strategies for direct, in-situ and high-throughput analysis, also in compliance with the principles of green analytical chemistry. Swab Touch Spray-Mass Spectrometry (Swab TS-MS) is a home-made AMS technique that involves the use of a medical swab as sampling tool and electrospray probe. To date, Swab TS-MS has been applied only for the analysis of small molecules, especially in forensic and medical fields, leaving the analysis of peptides and proteins still unexplored.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!