Minimally invasive surgery is the method of choice in endometrial cancer. Experience in procedures assisted by a robotic system is growing rapidly. One of the new bipolar ones is a Vessel Sealer, with sealing and cutting function. The aim of the study was to compare robotic surgery assisted with the da Vinci X system with use of the Vessel Sealer or without it. The study included 25 patients with high-risk endometrial cancer after completed pelvic and paraaortic lymphadenectomy with mean age 60.07 ± 10.67 (range 34.69-83.23) years divided into two groups: one with use of the Vessel Sealer; the second one only with monopolar scissors and subdivided by one-site versus dual docking. Duration of the operation was significantly associated with previous surgery (p < 0.005). Use of the Vessel Sealer was associated with lower blood loss during surgery (p < 0.05). The number of removal pelvic lymph nodes was higher in case of Vessel Sealer with no relation to BMI. Experience in robotic surgery allowed for shortened operation time and led to better outcomes. The Vessel Sealer used in robotic surgery appears to reduce blood loss during surgery and operation time, especially in the case of previous surgery, however, it increases costs of the procedure.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1038/s41598-025-93044-y | DOI Listing |
Sci Rep
March 2025
Neohospital, Kostrzewskiego 47, Cracow, Poland.
Minimally invasive surgery is the method of choice in endometrial cancer. Experience in procedures assisted by a robotic system is growing rapidly. One of the new bipolar ones is a Vessel Sealer, with sealing and cutting function.
View Article and Find Full Text PDFMed Devices (Auckl)
January 2025
Surgical Research and Development, Surgical Operating Unit, Medtronic, Lafayette, CO, USA.
Purpose: This study compared the performance of the new LigaSure™ XP Maryland Jaw Sealer/Divider (XP Maryland) to that of LigaSure Atlas™ (Atlas) and LigaSure™ Dolphin Tip (Dolphin Tip), two early LigaSure™ (LigaSure) devices characterized by consistent and reliable clinical performance.
Methods: Ex vivo bench testing on porcine renal arteries compared burst pressures, seal times, and rates of sticking, incomplete cuts, and charring between XP Maryland and Atlas and between XP Maryland and Dolphin Tip. In vivo acute testing on a porcine model compared thermal spread, seal times, and rates of hemostasis, sticking, and incomplete cuts between XP Maryland and the two early LigaSure devices.
Introduction Lymphocele is a typical complication of pelvic lymph node dissection (PLND) in robot-assisted radical prostatectomy (RARP). This study aimed to compare postoperative lymphatic leakage between the polymer ligation clip and vessel sealer, and evaluated the costs associated with the former. Methods The study enrolled patients who underwent RARP with PLND at our institution between April 2018 and March 2023 and were treated with a vessel sealer (LigaSure Blunt Tip 44 NC; Medtronic, Dublin, Ireland) until September 2021, and Hem-o-lok polymer ligation clips(Teleflex, Wayne, PA, USA) thereafter.
View Article and Find Full Text PDFUrogynecology (Phila)
March 2025
From the Division of Urogynecology, TriHealth, Cincinnati, OH.
Importance: Electrosurgical vessel sealing devices for vaginal hysterectomy have demonstrated reduced postoperative pain. This modality, however, has not been evaluated in patients undergoing vaginal hysterectomy with pelvic reconstruction.
Objective: The aim of the study was to describe postoperative pain levels utilizing the LigaSure vessel sealing device for vaginal hysterectomy in patients undergoing major reconstructive surgery.
Sci Rep
November 2024
Department of Nephro-urology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan.
This study evaluated the direct and indirect thermal effects of various surgical energy devices using an ex-vivo model. Two types of three devices were evaluated: ENSEAL™ X1 Curved Jaw Tissue Sealer (X1) and ENSEAL™ G2 Curved Tissue Sealer (G2) as vessel sealing systems (VSSs), and HARMONIC HD1000i Shears (HA) as an ultrasonic activating device (USAD). Each device was activated once under DRY or WET conditions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!