Background: Both ultraviolet B (UVB) phototherapy with 308-nm excimer light and excimer laser devices are widely used to treat vitiligo. While the devices share the 308-nm wavelength, they have distinct characteristics. Notably, the excimer laser exhibits laser properties (monochromatic coherent light) and unique device specifications (a high frequency of 400 Hz and a remarkably high irradiance of 83 million mW/cm). This study compared excimer light and laser irradiation, focusing on the depth of penetration into hair follicles and the effects on activation of melanocyte lineage cells, including melanocyte stem cells (McSCs) and melanoblasts.

Methods: We irradiated the dorsal skin of mice with both devices at 1,000 mJ/cm. Samples taken at 15 min and 3, 24, and 72 h after irradiation were used for immunostaining analysis. We evaluated penetration depth by using the staining pattern of cyclobutane pyrimidine dimers (CPDs), induction of apoptosis by using a terminal deoxynucleotidyl transferase-mediated deoxy-uridine triphosphate nick end-labeling (TUNEL) assay, and activation of melanocyte lineage cells by using fluorescent double immunostaining for TRP2 and β-catenin.

Results: The excimer laser induced significantly more CPDs in the deeper regions of hair follicles while causing significantly faster removal of CPDs and less apoptosis in the epidermis. Moreover, the percentage of TRP2-positive cells with nuclear β-catenin in the follicles was significantly higher with the excimer laser.

Conclusions: As compared with excimer light, the excimer laser penetrated more deeply into hair follicles, resulted in fewer epidermal side effects, and activated significantly more melanocyte-lineage cells.

Download full-text PDF

Source
http://dx.doi.org/10.1272/jnms.JNMS.2025_92-110DOI Listing

Publication Analysis

Top Keywords

excimer laser
20
hair follicles
16
excimer light
16
melanocyte lineage
12
lineage cells
12
excimer
10
light excimer
8
compared excimer
8
activation melanocyte
8
cells
6

Similar Publications

Boosting the Pixel Acquisition Rate of Elemental Mapping with Laser Ablation-ICP-Mass Spectrometry to 1000 Hz.

Anal Chem

March 2025

Department of Chemistry, Atomic and Mass Spectrometry - A&MS Research Group, Ghent University, Campus Sterre, Krijgslaan 281-S12, Ghent 9000, Belgium.

Novel low-dispersion ablation cell designs and highly efficient aerosol transport systems have enabled fast elemental mapping using laser ablation-ICP-mass spectrometry (LA-ICP-MS) at high spatial resolution and its application in various research fields. Nowadays, the fastest low-dispersion setups enable narrow single pulse responses (SPR, duration of the transient signal observed upon a single laser shot), which enhance the signal-to-noise ratio and boost the pixel acquisition rate attainable in elemental mapping applications. In this work, the analytical performance of a nanosecond 193 nm ArF* excimer-based kHz laser in combination with a low-dispersion tube-type ablation cell, coupled to an ICP-mass spectrometer equipped with a time-of-flight (ToF) analyzer, was evaluated.

View Article and Find Full Text PDF

Effects of effective optical zone and decentration on visual quality after smile for different astigmatism types.

BMC Ophthalmol

March 2025

State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Sun Yat-sen University, Guangzhou, 510060, China.

Purpose: To compare the refractive outcomes and visual quality among different types of astigmatism following SMILE and evaluate effective optical zone (EOZ) features, decentration and their potential effects on visual quality.

Methods: This study included 101 left eyes of 101 patients who underwent SMILE. Patients were grouped according to astigmatism types (with-the-rule [WTR], against-the-rule [ATR] and oblique astigmatism) and decentered displacement (major axis > minor axis and major axis < minor axis).

View Article and Find Full Text PDF

ObjectivesProximal to mid-term effects of contrast excimer laser atherectomy (ELA) + drug-coated balloon (DCB) versus PTA + drug-coated balloon (DCB) in the treatment of new lesions in the femoral popliteal segment of patients with lower extremity arteriosclerosis and occlusion.MethodsThe clinical data of 105 patients with CT-confirmed femoropopliteal segment lesions (Rutherford grades 3-6) were retrospectively analyzed. According to the computerized randomization method, 58 patients (44 males, mean 72.

View Article and Find Full Text PDF

Background: Vitiligo, a prevalent acquired depigmentation condition, involves a progressive melanocyte loss, posing significant treatment challenges. Excimer light has been employed in vitiligo treatment, while trichloroacetic acid (TCA) has been noted to induce chemical trauma, leading to perifollicular pigmentation and perilesional repigmentation in vitiligo. This study aims to assess and compare the efficacy and safety of using 308 nm monochromatic excimer light alone versus combining it with 50% TCA in treating vitiligo.

View Article and Find Full Text PDF

Purpose: To evaluate the repeatability of angle kappa measurements obtained from the Pentacam (Oculus Optikgeräte GmbH), Sirius (Costruzione Strumenti Oftalmici), and Keratron Scout (BVI), and to assess the agreement with those obtained from the Amaris 750S (SCHWIND eye-tech-solutions).

Methods: This study included 110 patients scheduled to undergo transepithelial photorefractive keratectomy or femtosecond laser-assisted laser in situ keratomileusis. Before surgery, each patient underwent angle kappa measurement using three instruments: Pentacam, Sirius, and Keratron.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!