Nickel-containing devices, such as the Amplatzer PFO Occluder and Gore® Cardioform Septal Occluder (GSO), are used for transcatheter patent foramen ovale (PFO) closure. However, the impact of nickel hypersensitivity on post-procedural outcomes remains poorly understood. This study aimed to evaluate the risk of adverse events, in patients with nickel hypersensitivity undergoing PFO closure. Our study was a prospective, double-blinded, randomized study enrolling patients with cryptogenic stroke and PFO-related ischemic stroke to receive either the Amplatzer or GSO device. Nickel hypersensitivity was assessed using skin patch testing. The primary endpoint was the incidence of device syndrome, a composite of patient-reported symptoms (chest pain, palpitations, migraines, dyspnea, and rash). Of the 96 patients, 28 (29.2%) had nickel hypersensitivity. The incidence of device syndrome was significantly higher in patients with nickel hypersensitivity compared to those without (71.4% vs. 20.6%, p < 0.001). Specifically, new-onset or worsening migraines and palpitations were more frequent in nickel-hypersensitive patients. No significant differences were observed in documented arrhythmias, bleeding, or stroke. Multivariable analysis showed that nickel hypersensitivity was associated with a 10.5-fold increase in the odds of device syndrome (aOR = 10.53, 95% CI: 3.17-35.00, p < 0.001). The incidence of device syndrome was similar for both devices. Patients with nickel hypersensitivity are at significantly higher risk for developing device syndrome after PFO closure. Both the Amplatzer and GSO devices demonstrated comparable safety and efficacy in this population. These findings highlight the need for further research to optimize device selection and improve outcomes in nickel-hypersensitive patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1161/CIRCINTERVENTIONS.125.015228 | DOI Listing |
Circ Cardiovasc Interv
March 2025
Unit of Structural Heart Diseases, First Department of Cardiology, National and Kapodistrian University of Athens, Hippocration General Hospital of Athens, Athens, Greece; First Department of Cardiology, National and Kapodistrian University of Athens, Hippocration General Hospital of Athens, Athens, Greece.
Nickel-containing devices, such as the Amplatzer PFO Occluder and Gore® Cardioform Septal Occluder (GSO), are used for transcatheter patent foramen ovale (PFO) closure. However, the impact of nickel hypersensitivity on post-procedural outcomes remains poorly understood. This study aimed to evaluate the risk of adverse events, in patients with nickel hypersensitivity undergoing PFO closure.
View Article and Find Full Text PDFDrug Deliv Transl Res
March 2025
Department of Bioengineering, University of Pittsburgh, 302 Benedum Hall, 3700 O'Hara Street, Pittsburgh, PA, 15260, USA.
Allergic contact dermatitis (ACD), a T-cell mediated inflammatory skin condition, is prompted by multiple, subsequent exposures to contact allergens (e.g., nickel).
View Article and Find Full Text PDFJ Orthop
March 2025
Department of Clinical Orthopedics, University of Florence, A.O.U. Careggi CTO - Largo Palagi 1, 50139 Florence, Italy.
Background: Metal hypersensitivity in Total Knee Arthroplasty (TKA) continues to intrigue surgeons and researchers, with significant limitation of allergy tests due to the absence of clear cut-offs for a definitive diagnosis and their limited diffusion worldwide. We analyzed the literature to compare clinical outcomes in patients with metal hypersensitivity undergoing hypoallergenic knee arthroplasties and subjects without metal allergy undergoing standard knee arthroplasties.
Methods: This review adhered to PRISMA guidelines.
Microbiol Spectr
March 2025
Engineering Research Center of Southwest Animal Disease Prevention and Control Technology, Ministry of Education of the People's Republic of China, Chengdu, China.
Zinc (Zn) is essential for all bacteria, but excessive Zn levels are toxic. Bacteria maintain zinc homeostasis through regulators, such as Zur, AdcR, and ZntR. is a significant pathogen causing acute serositis in ducks and other birds.
View Article and Find Full Text PDFArch Dermatol Res
March 2025
Department of Dermatology, Air Force Medical Center of PLA, No. 30 Fucheng Road, Haidian District, Beijing, 100142, China.
Objective: This study presents a comprehensive analysis of patch test results in a cohort of 716 pediatric patients diagnosed with type IV hypersensitivity dermatosis. The aim is to provide valuable insights for the prevention and treatment of type IV hypersensitivity dermatosis in the pediatric population.
Methods: A prospective study was conducted from August 2021 to October 2023, enrolling pediatric patients with type IV hypersensitivity dermatosis attending the Department of Dermatology at the prestigious Air Force Medical Center.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!