A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1057
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3175
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Study on indoor thermal environment and energy consumption of traditional dwellings of ethnic minorities in Sichuan plateau. | LitMetric

Study on indoor thermal environment and energy consumption of traditional dwellings of ethnic minorities in Sichuan plateau.

Sci Rep

Key Laboratory of Spatial Intelligent Planning Technology, Ministry of Natural Resources, Shanghai, China.

Published: March 2025

In this paper, field tests, questionnaire surveys, and DesignBuilder were used to analyse the indoor thermal environment and energy consumption of traditional houses in a traditional ethnic minority village of Western Sichuan Plateau of China, The results showed that during the summer test period, the outdoor temperature range was 9.3-7.8 °C and the relative humidity range was 53.5-67.4%, while the indoor temperature range of the tested room was 13.3-2.3 °C, and the relative humidity range was 69.1-83.0%. The humidity is high, and the thermal environment does not meet the requirement of local standard. Therefore, corresponding energy-saving optimization measures are proposed. In the winter heating building model data, compared with the heat load before optimization, the energy saving reaches about 56.5%. In addition, the carbon emissions and economic suitability of different heating methods were evaluated. Electric heating, coal-fired heating and biomass heating have payback periods of 11 years, 24 years and 6 years respectively. With perspective focusing on the special regional and ethnic characteristics of the plateau, this research aims to promote energy conservation and sustainable development of local traditional buildings of ethnic minorities, and help improve the living environment of the Sichuan Plateau. In the future, a long-term monitoring mechanism can be established to continuously track residential buildings after the adoption of optimization measures to evaluate the actual effect of these measures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11890585PMC
http://dx.doi.org/10.1038/s41598-025-93002-8DOI Listing

Publication Analysis

Top Keywords

thermal environment
12
sichuan plateau
12
indoor thermal
8
environment energy
8
energy consumption
8
consumption traditional
8
ethnic minorities
8
temperature range
8
relative humidity
8
humidity range
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!