Statement Of Problem: The seal at the implant-abutment connection (IAC) is crucial for ensuring implant-prosthetic function and reducing the risk of peri-implant diseases. An accurate determination of the first IAC gap under realistic dynamic-loading conditions is needed to investigate current and future IAC designs.
Purpose: The purpose of this in vitro study was to use a novel method of determining the load and probability of occurrence of the elastic first IAC gap that overcomes most of the limitations of the representative IACs currently available.
Material And Methods: Three flat-straight and 4 conical-tapered connections with varying abutment cone angles with 8 specimens per configuration (n=8) were tested with an in situ loading experiment underwater by following the International Organization for Standardization (ISO) 14801 standard. Before load application, the IACs were filled with toluidine, and the screws tightened to 35 Ncm. Incremental loading of 20 N was applied over 1000 cycles until leakage was detected by a video recording macro-equipped camera. Differences between the means were determined by 1-way ANOVA (α=.05). The probability of gap occurrence was calculated from the data obtained based on the maximum occlusal force values reported in literature.
Results: The method allowed the detection of the first IAC gap in the elastic regime. Flat connections showed a linear relationship between connection diameter and the first gap load ranging from 140.0 ±21.4 N (Ø3.0 mm) to 255.0 ±31.6 N (Ø4.1 mm). On Ø3.5 mm connections, the gap at flat connections opened at 193.8 ±22.0 N, while, at conical connections, the loads needed were significantly lower and the dispersion higher, irrespective of the angle between the abutment and the implant connection cones: 135.0 ±80.5 N (0 degrees), 100.0 ±54.5 N (0.4 degrees, P<.05), 77.5 ±37.7 N (0.8 degrees, P<.05) and 82.5 ±49.5 N (1.2 degrees, P<.05). Consequently, conical connections had a higher probability of gaps, particularly in the posterior zone, ranging from 8.2% to 29.0% of the reported mastication force.
Conclusions: This innovative in situ leakage detection method enabled the identification of disparities in the masticatory load at which initial gaps occurred across various flat and conical IAC configurations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.prosdent.2025.02.013 | DOI Listing |
J Prosthet Dent
March 2025
Researcher, Department of Biomechanics, BTI Biotechnology Institute I + D, Miñano, Spain.
Statement Of Problem: The seal at the implant-abutment connection (IAC) is crucial for ensuring implant-prosthetic function and reducing the risk of peri-implant diseases. An accurate determination of the first IAC gap under realistic dynamic-loading conditions is needed to investigate current and future IAC designs.
Purpose: The purpose of this in vitro study was to use a novel method of determining the load and probability of occurrence of the elastic first IAC gap that overcomes most of the limitations of the representative IACs currently available.
In recent years, several algorithms have been developed for the segmentation of the Inferior Alveolar Canal (IAC) in Cone-Beam Computed Tomography (CBCT) scans. However, the availability of public datasets in this domain is limited, resulting in a lack of comparative evaluation studies on a common benchmark. To address this scientific gap and encourage deep learning research in the field, the ToothFairy challenge was organized within the MICCAI 2023 conference.
View Article and Find Full Text PDFDrug Alcohol Rev
March 2025
SHORE & Whariki Research Centre, College of Health, Massey University, Auckland, New Zealand.
Introduction: Considerable evidence exists on the most effective policy to reduce alcohol harm; however, a tool and index to allow comparisons of policy status of the most effective policies between similar jurisdictions and change over time within a jurisdiction has not been widely used. The International Alcohol Control (IAC) Policy Index is designed to address this gap and monitor the alcohol policy environment with regard to four effective policy domains (tax/pricing, availability, marketing and drink driving).
Methods: This study compares IAC Policy Index scores across 11 high-income jurisdictions: Aotearoa (Māori language name for New Zealand); Australia; Finland; Norway; the Netherlands; (Republic of Ireland; Lithuania; Ontario; Alberta; Quebec; British Columbia).
Clin Implant Dent Relat Res
February 2025
Minnesota Dental Research Center for Biomaterials and Biomechanics, School of Dentistry, University of Minnesota, Minneapolis, Minnesota, USA.
Objectives: This study evaluated different designs of the conical implant-abutment connection (IAC) and their resistance to microgap formation under oblique loads as specified by the ISO standard for testing dental implants. Also evaluated was the effect of deviations from the ISO specifications on the outcomes.
Methods: Finite element analysis was conducted to compare the microgap formation and stress distribution among three conical IAC designs (A, B, and C) in two loading configurations: one compliant with ISO 14801 and one with a modified load adaptor (non-ISO).
Mycoses
October 2024
Department of Infectious and Parasitic Diseases, School of Medicine, University of São Paulo, São Paulo, Brazil.
Background: Invasive candidiasis (IC) represents a significant threat to both mortality and morbidity, especially among vulnerable populations. Intra-abdominal candidiasis (IAC) frequently occurs in critically ill and cancer patients, with these specific groups carrying a heightened risk for such invasive fungal infections. Despite this, there is a noticeable lack of attention to IAC in cancer patients within the literature, highlighting a critical gap that requires urgent consideration.