Cystometry is a urodynamic investigation used to examine the pressure-volume relationship during bladder filling. In clinical practice, cystometry is typically performed with water or air-filled catheters connected to an external transducer. These catheters, which are primarily suited for short-duration measurements, can compromise pressure transmission due to air bubbles, clogging, bending, and movements, and they are not sensitive enough to rapid pressure fluctuations. Moreover, ensuring proper leveling of the transducer is crucial for accurate measurement. To overcome these limitations, a MEMS pressure sensor prototype was previously developed. This study now evaluates the concurrent validity and reliability of this prototype against a conventional cystometry system during a series of clinical cases involving 33 patients undergoing routine cystometry. Excluding three sensors for which a correct placement during cystometry could not be verified, 83.3% of sensors produced useful data. Among these, 88% demonstrated a strong correlation with the reference system in the time-amplitude domain and 72% exhibited a high correlation in the time-frequency domain. Although these sensors were manually assembled and did not go through a standardized manufacturing process to enhance stability and detect potential failures, over 78.8% of the 33 sensors tested remained functional after the trial. Therefore, these results support the adoption of this technology in clinical practice, as it may improve diagnostic efficiency, reduce patient discomfort, and potentially be used for long-term and ambulatory urodynamics.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2025.117320DOI Listing

Publication Analysis

Top Keywords

clinical practice
8
sensors
5
cystometry
5
urodynamics mems-based
4
pressure
4
mems-based pressure
4
pressure sensors
4
clinical
4
sensors clinical
4
clinical validation
4

Similar Publications

Innovative care models: Expanding nurses' and optometrists' roles in ophthalmology.

Nurs Ethics

March 2025

Yong Loo Lin School of Medicine, National University of Singapore, Singapore; Uehiro Oxford Institute, University of Oxford.

The expanding demands of healthcare necessitate novel methods of increasing the supply of trained professionals to enhance the delivery of care services. One means of doing so is to expand allied health professionals' scope of practice. This paper explores the ethics of two examples of such expansion in ophthalmology, comparing the widely accepted practice of nurses administering intravitreal injections and the relatively less prevalent optometrists functioning as physician extenders.

View Article and Find Full Text PDF

Risk Prediction Models for Sentinel Node Positivity in Melanoma: A Systematic Review and Meta-Analysis.

JAMA Dermatol

March 2025

Department of Surgery, Arthur J.E. Child Comprehensive Cancer Centre, University of Calgary, Calgary, Alberta, Canada.

Importance: There is a need to identify the best performing risk prediction model for sentinel lymph node biopsy (SLNB) positivity in melanoma.

Objective: To comprehensively review the characteristics and discriminative performance of existing risk prediction models for SLNB positivity in melanoma.

Data Sources: Embase and MEDLINE were searched from inception to May 1, 2024, for English language articles.

View Article and Find Full Text PDF

Importance: Tenecteplase is an alternative to alteplase for emergency treatment of acute ischemic stroke. However, limited data are available comparing their clinical effectiveness in routine clinical practice.

Objective: To compare short-term effectiveness and safety outcomes for patients with ischemic stroke treated with intravenous tenecteplase vs alteplase.

View Article and Find Full Text PDF

Background: Body dysmorphic disorder (BDD), characterized by an obsessive focus on perceived flaws in appearance and affects approximately 0.7% through 2.4% of the general population, with dental-related concerns accounting for 20% of cases.

View Article and Find Full Text PDF

Purpose: To enhance patient safety and improve communication and response times during the perioperative management of patients with acute upper gastrointestinal bleeding, a checklist was developed, tested for psychometric properties, and implemented in clinical practice.

Design: This is a methodological study.

Methods: A perioperative checklist for acute upper gastrointestinal bleeding was developed using a literature review and the Delphi method.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!