Objectives: To examine CT radiation dose variation in PET-CT and understand how often providers use diagnostic vs lower doses for attenuation correction and anatomic localization (AC/AL).
Methods: Retrospective, multi-centered study of PET-CT exams from 2010 to 2021. Exams were categorized as body or brain. Radiation dose was quantified using dose length product (DLP), adjusted for patient size (DLP), and for size and scan length (DLP). DLP variation was assessed by body region and facility. To ascertain whether sites use AC/AL or diagnostic doses, we compared each facility's DLP in CTs from PET-CT vs diagnostic CT exams of analogous body regions (not associated with PET), controlling for scan length using DLP. Lastly, we categorized exams as likely diagnostic if they used multiple phases and/or contrast to compare dose and frequency with likely non-diagnostic exams.
Results: Sixty-four thousand two hundred ten exams included 93% body, 7% brain. Doses were higher and more variable in the body than brain exams (adult mean DLP = 1004 vs 341 mGy-cm, respectively). For body exams, DLP was higher in older children than adults, and there was wide inter-facility variation (median DLP range = 245-2391 mGy-cm). Most facilities used higher CT doses in body PET-CT than in diagnostic CT exams even controlling for scan length. Fifty-three percent of adult and 76% of child body exams were likely diagnostic based on the use of diagnostic techniques.
Conclusion: While diagnostic CT is sometimes indicated for PET-CT, body exams generally do not use AC/AL protocols. Doses were higher than previously reported, higher than analogous diagnostic CT exams, and higher in older children than adults when size adjusted.
Key Points: Question How does CT radiation dose vary in PET-CT and how often do providers use diagnostic vs lower doses for AC/AL? Findings Most facilities did not use AC/AL protocols for body PET-CT, and CT effective doses were higher than previously reported. Clinical relevance The considerable inter-facility variation observed suggests ample opportunity to reduce ionizing radiation doses for CT in body PET-CT by adopting low-dose (AC/AL) protocols and other dose reduction techniques.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00330-025-11391-w | DOI Listing |
Front Bioeng Biotechnol
February 2025
Brain Tumor Center & Neuro-Oncology Unit, Beth Israel Deaconess Medical Center, Boston, MA, United States.
Purpose: Tumor Treating Fields (TTFields) are delivered by transducer arrays applied to scalp or body surface for treatment of multiple malignancies. Dermatologic complications are thought to be related to hydrogel situated between the electrodes and scalp or skin to facilitate electric field penetration. High intensity of TTFields on these surfaces may also be a contributing factor.
View Article and Find Full Text PDFInt J Gen Med
March 2025
Department of Imaging, Lianyungang First People's Hospital, Lianyungang, Jiangsu, People's Republic of China.
Introduction: The traditional injection method of contrast media (CM) has limitations in terms of volume and imaging quality. Choosing the optimal CM injection method is crucial for ensuring high-quality images and accurate diagnosis in triple-rule-out computed tomography angiography (TRO-CTA). This study aims to investigate the application value of combining region of interest (ROI) with CM injection method alterations in TRO-CTA.
View Article and Find Full Text PDFJ Appl Clin Med Phys
March 2025
Division of Radiation Biophysics, Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts, USA.
Current radiotherapy machines intended to perform streamlined online adaptive therapy are designed to be standalone, which makes it challenging to integrate them with the rest of the clinic. This work describes the installation of a standalone CT-guided online adaptive system, the Varian Ethos, in a busy clinic utilizing products from multiple vendors, including RayStation as the treatment planning system (TPS) and MOSAIQ as the oncology information system (OIS). The aim was to develop solutions that minimized workload increases for staff using redundant systems and to implement this new technology safely, with no increase in safety reports resulting from its integration into the clinic.
View Article and Find Full Text PDFRadiat Oncol
March 2025
Department of Cardiology, Institute for Clinical and Experimental Medicine, Videnska 9, Prague, 14000, Czech Republic.
Background: This intervention pilot case series assessed 40-Gy stereotactic radiosurgery (SRS) neuromodulation applied to the bilateral stellate ganglion (SG) as a bailout procedure for patients with refractory angina pectoris (RAP).
Materials And Methods: The local institutional review board approved this feasibility study. In three patients with RAP, after repeated good response, symptoms were temporarily relieved after anaesthetic blockade of the left SG under ultrasound guidance.
Sci Rep
March 2025
Medical Physics and Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Sciences and Technology, Kaohsiung, 80778, Taiwan, ROC.
In radiation therapy, precise dose distribution is essential for minimizing damage to normal tissues. Gafchromic EBT3 film is widely used to assure the quality of two-dimensional dosimetry but requires frequent recalibrations due to changes in sensitivity over time. This study presents a new calibration method using a Keras-based generalized additive neural network (GANN) to address film aging.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!