A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3145
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Detectability of acute ischemic stroke with thin (3 mm) axial versus thin (3 mm) coronal diffusion-weighted imaging in patients presenting to the emergency department with acute dizziness. | LitMetric

Background And Purpose: Ischemic strokes can cause vertigo, particularly when involving the posterior circulation of the brain. Prior research has suggested that thin-Sect. (3 mm) axial or coronal DWI may improve the detection of ischemic stroke compared to thick (5 mm) DWI. However, relative sensitivity of differing thin DWI sequences is unknown. In this retrospective cohort study, we compare the sensitivity of thin coronal DWI and thin axial DWI in detection of brain ischemia.

Materials And Methods: Retrospective study at a single institution (2/18/2020-8/31/2023) of patients who presented to the emergency department with vertigo/dizziness and underwent an abbreviated MRI protocol (3 mm axial DWI, 3 mm coronal DWI, axial FLAIR, and axial SWI). For each case with an ischemic lesion, the visibility of infarct on thin axial and coronal DWIs was rated; location and size were also recorded. Visibility on either sequence was considered the reference standard. Sensitivity was compared with McNemar's test.

Results: 615 abbreviated MRI examinations were performed; 24/615 (3.9%) had an ischemic lesion (15 cerebral, 7 brainstem, 13 cerebellar). 24 of these MRI examinations with ischemic lesions were performed using 3 mm axial MRI and on 3T MRI. All lesions (24/24) were visible on thin axial DWI (100% sensitivity, 95% CI: 0.95-1.00). Fewer lesions (20/24) were seen on thin coronal DWI (83% sensitivity, 95% CI: 0.72-0.91). The difference in sensitivity was statistically significant (p = 0.0374). Lesions not visible on coronal DWI were 2-8 mm in size, the largest in the middle cerebellar peduncle.

Conclusions: Thin coronal DWI may not improve additional diagnostic utility beyond thin axial DWI for the detection of ischemia in patients with dizziness. When designing protocols tailored for stroke detection (particularly in the posterior circulation), replacing conventional (5 mm) DWI with thin (3 mm) axial DWI may be preferable to adding a thin coronal sequence.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10140-025-02327-4DOI Listing

Publication Analysis

Top Keywords

coronal dwi
24
axial dwi
20
3 mm axial
16
thin coronal
16
thin axial
16
dwi
14
thin
12
thin 3 mm
12
axial
11
coronal
9

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!