Objectives: To compare the outcomes of comminuted patella fractures fixed with a new patella-specific 2.7mm variable angle (VA) locking plate in isolation versus when augmentation of fracture fixation is applied with the plate.

Methods: Design:Retrospective.

Setting: Academic Level I Trauma Center.

Patient Selection Criteria: All acute comminuted patella fractures (AO/OTA 34-C3; complete displaced or undisplaced articular, frontal/coronal multifragmentary fractures) in adult patients primarily treated with a new patella-specific 2.7 mm VA locking plate (Synthes, Paoli, PA) between January 2021 and February 2024 at a single academic center were reviewed and divided in those fixed with the patella plate alone and those with additional bony and/or soft tissue augmentation. Excluded were those with < 90 follow-up, set a priori, unless complications occurred <90 days.

Outcome Measures And Comparisons: Comparison of patient age, sex, BMI, ASA, FRAX score, open fracture, polytrauma involvement, length of follow-up and post-operative protocols was made between groups. The primary outcome measure was loss of fixation. Secondary outcomes were mode of failure and other surgical complications.

Results: There were a total of 38 included patients, with no lack of or loss of follow-up, with 20 grouped into patella plate alone, and 18 into patella plate plus augmentation. The plate only group had a higher mean age (63.7 vs. 46.9, p=0.024), with no between-group differences in sex (65% vs. 44% female, p=0.20), BMI (p=0.51), 10-year fracture risk (FRAX) (p=0.06), open fractures (p=0.30), polytrauma involvement (p=0.97), or postoperative weight-bearing (p=0.76) or range of motion (p=0.06) protocols. There were eight failures (40.0%) in the plate-only group, and two failures in the plate with augmentation group (11.1%); (p=0.043). When controlling for known risk factors for osteoporosis and poor bone quality using the FRAX 10-year fracture risk on multivariable regression analysis, plate fixation with fracture augmentation was associated with a lower risk of fixation failure (OR=0.14, 95% CI 0.02-0.75; p=0.036). The plate-only group failed by loss of distal (62.5%, n=5) and proximal fixation (37.5%, n=3). Each of the two failures in the plate plus augmentation group had loss of distal fixation.

Conclusions: Treatment of comminuted patella fractures with a new patella-specific 2.7mm VA locking plate has a high failure rate when used in isolation. Augmenting fracture fixation with soft-tissue repair and/or independent fracture fragment fixation may significantly decrease failure rates. In particular, augmentation of the tendon avulsion component to restore the extensor mechanism appears critical.

Level Of Evidence: Therapeutic Level 3.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BOT.0000000000002972DOI Listing

Publication Analysis

Top Keywords

comminuted patella
12
patella fractures
12
locking plate
12
fractures ao/ota
8
ao/ota 34-c3
8
variable angle
8
angle locking
8
patella
5
high failure
4
failure rates
4

Similar Publications

Objectives: To compare the outcomes of comminuted patella fractures fixed with a new patella-specific 2.7mm variable angle (VA) locking plate in isolation versus when augmentation of fracture fixation is applied with the plate.

Methods: Design:Retrospective.

View Article and Find Full Text PDF

Patellar fractures are rare but clinically significant due to their impact on knee function. These injuries vary from simple transverse to complex comminuted patterns. Computed tomography (CT) offers superior visualization compared to radiographs, enabling accurate classification and surgical planning.

View Article and Find Full Text PDF

Patellar fractures are potentially debilitating injuries due to loss of extensor mechanism function, resulting in an inability to extend the leg. Traditionally, these fractures have been surgically managed with open reduction and internal fixation using a tension band construct. This can be performed with K-wires or cannulated screws with suture or cable as the tension band.

View Article and Find Full Text PDF

Objective: Inferior pole patellar fractures (IPPFs) pose a significant challenge due to their complex fracture patterns and high risk of complications associated with current treatment methods. This study aims to (1) characterize the fracture patterns of IPPFs using fracture mapping and (2) compare the biomechanical stability and clinical outcomes of treatment with anchor suture with patellar cerclage versus Kirschner-wire tension band combined with patellar cerclage.

Methods: (1) A retrospective analysis was conducted on 61 patients with IPPF.

View Article and Find Full Text PDF

Objective: The treatment of comminuted inferior pole patellar fractures has long posed a challenge for orthopedic surgeons. This study aims to compare the biomechanical stability and clinical efficacy of Kirschner wire tension band combined with anchor cross-suture fixation versus traditional partial patellectomy in the treatment of comminuted inferior pole patellar fractures.

Methods: A retrospective analysis was conducted on 14 patients who underwent Kirschner wire tension band combined with anchor cross-suture fixation (Group A) in our department of orthopedics from September 2020 to April 2022.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!